audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Renewing needle bearings (polygon bearings) for flange shaft (right-side) > < Removing and installing flange shaft (right-side)
Renewing flange shaft oil seal (right-side) at bevel box (outer seal)
Renewing flange shaft oil seal (right-side) at bevel box (outer seal)
Special tools and workshop equipment required
   
t  Thrust piece -T10049-
t  Sealing grease → Electronic parts catalogue
Procedure
  Note
t  The oil seal can be renewed with the gearbox installed.
t  → Chapter „Repair instructions“.
t  → Chapter „Rules for cleanliness when working on the gearbox“.
–  Remove flange shaft (right-side) → Chapter.
–  Pry out flange shaft oil seal using assembly lever.
  W00-1004
–  Drive in new oil seal as far as stop using thrust piece -T10049-.
  N39-0764
–  Pack space between sealing lip and dust lip -arrow- half full with sealing grease → Electronic parts catalogue.
–  Install flange shaft (right-side) → Chapter.
–  → Chapter „Checking and topping up oil level in bevel box“.
  N32-0001

Renewing needle bearings (polygon bearings) for flange shaft (right-side) > < Removing and installing flange shaft (right-side)