Workshop Manuals Factory service & repair Audi
01 Servicing 6-cylinder TDI engine, common rail (EA 897 Gen. I)02 4-cylinder TDI engine, 2.0 ltr. 4-valve common rail (EA 288 Gen. I)03 Servicing 4-cylinder TDI engine, common rail (EA 288 Gen. I)04 6-cylinder TDI engine, 3.0 ltr. 4-valve common rail (EA 897 Gen. I)05 Fuel supply system06 4-cylinder direct injection engine (2.0 ltr. 4-valve TFSI, EA 888 Gen. III, B cycle)07 Servicing 4-cylinder engine, 2.0 ltr. 4-valve TFSI (EA 888, Gen. III BZ)08 4-cylinder direct injection engine (1.8, 2.0 ltr. 4-valve TFSI - generation III)09 4-cylinder direct injection engine (1.4 ltr. 4-valve TFSI, EA 211)10 Technical data for engines11 Servicing 7-speed dual clutch gearbox 0CJ, 0CL, 0CK12 Rear final drive 0D2, 0D3, 0DB13 8-speed automatic gearbox 0D514 7-speed dual clutch gearbox 0CJ, 0CK, 0CL15 6-speed manual gearbox 0CS, 0DJ, 0CX16 Servicing 6-speed manual gearbox 0CS, 0DJ, 0CX17 Running gear: Specifications for testing the braking force (according to German legislation)18 Running gear: Wheel/Tyre Guide19 Brake system20 Running gear, axles, steering21 Heating, air conditioning22 Heating and air conditioning: Auxiliary heater, supplementary heater23 Electrical system24 Electrical: Communication25 General body repairs, interior26 General body repairs, exterior
Audi A4 Mk4 (2015-2023)21 · Heating, air conditioning
21 · Heating & A/C

Removing and installing front expansion valve

Make
Audi
Model
A4 Mk4
Year
2015–2023
Section
Refrigerant circuit › Removing and installing front expansion valve
Heating, air conditioningRemoving and installing front expansion valve

Removing and installing front expansion valve

Air conditioner with refrigerant R134a

Note

  • After the air conditioner compressor is switched off, it might take a relatively long period on this vehicle before the pressure in the high-pressure side drops (the expansion valve is cold and the pressure in the low-pressure side increases rapidly after the compressor is switched off, the expansion valve is closed and the refrigerant can flow to the low-pressure side only slowly). If the air conditioner compressor is switched on, the pressure in the low-pressure side drops, the expansion valve is opened and the refrigerant can flow to the low-pressure side.

Removing

Switch off ignition.

Discharge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.

Remove the plenum chamber cover General body repairs, exteriorRep. gr.50Bulkhead; Removing and installing plenum chamber cover.

Note

  • The plenum chamber cover must be intact to stop water running into the heater and air conditioning unit via the intake housing with the plenum chamber cover fitted. The plenum chamber cover must also be properly and fully engaged in the windscreen frame General body repairs, exteriorRep. gr.50Bulkhead; Removing and installing plenum chamber cover.

Unscrew the nut (A), tightening torque Chapter“Exploded view - components beneath wing and in plenum chamber”.

A87-12100

Detach the two refrigerant lines (B, C) from the expansion valve (D) at the front and lay aside (do not remove) Chapter“Detaching refrigerant lines from front expansion valve/re-attaching”.

Screw out the bolts (A).

A87-11745

Detach expansion valve (B) from refrigerant lines to evaporator.

Note

  • Seal open line connections at the connection point with clean plugs for example from the engine bung set VAS 6122.

Installing

A87-11746

Install in reverse order, paying attention to the following:

Make sure that the support ring (D) is correctly positioned and check the grommet in the back wall of the plenum chamber for damage and proper installation.

Clean the connecting pipes (B) and (C) to the evaporator and check for damage.

Check the mounting plate (D) on the connecting pipes (B) and (C) for correct positioning on the connecting pipes to the evaporator.

Replace the O-rings (E) and (F); for version refer to Electronic parts catalogue.

Note

  • Heed the fitting instructions for O-rings Chapter“Refrigerant circuit seals”.
  • The mounting plate (A) must be inserted in the mounts of the connecting pipes (B) and (C).
A87-11813
  • The O-rings (D) and (E) are inserted in the grooves of the connecting pipes (B) and (C)(arrows).

Moisten O-rings slightly with refrigeration oil before fitting Chapter“Refrigerant circuit seals”.

Clean the connections at the expansion valve (A) (to the connecting pipes (C) and (E)) to the evaporator and check for damage.

A87-11747

Note

  • There are various versions of the expansion valve (A) (identical housing but different characteristic control curve). Attention is therefore to be paid to the exact assignment Electronic parts catalogue.

Replace the O-rings (B) and (F); for version refer to Electronic parts catalogue.

Pay attention to correct positioning of the mounting plate (D) on the connecting pipes (C) and (E) to the evaporator.

Tighten bolts (G).

Tightening torque: 9 Nm.

Attach the refrigerant line to the expansion valve Chapter“Detaching refrigerant lines from front expansion valve/re-attaching”.

Evacuating and charging refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.

Re-install remaining components (removed earlier).

Interrogate the event memory of the front air conditioner operating and display unit E87 and erase any faults displayed Vehicle diagnostic tester“Guided fault-finding” mode.

Start up the air conditioner after charging the refrigerant circuit Chapter“Starting up air conditioner after charging refrigerant circuit”.

Note

  • Also heed the information on start-up of the air conditioner after charging Air conditioner with refrigerant R134aRep. gr.87General information on air conditioner.

Parts & tools for this job For 2015 Audi A4