Separating refrigerant lines from condenser/connecting
- Make
- Audi
- Model
- A4 Mk4
- Year
- 2015–2023
- Section
- Refrigerant circuit › Separating refrigerant lines from condenser/connecting
Separating refrigerant lines from condenser/connecting
Warning Danger from the escape of pressurised refrigerant.
Frostbite on the skin and other parts of the body.
- Always drain the refrigerant circuit before slackening off the bolts at the connection points.
Note
- There are different condenser versions depending on the vehicle model Electronic parts catalogue.
Switch off the ignition.
Drain the refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.
Remove the left air intake grille General body repairs, exteriorRep. gr.63Front bumper; Removing and installing add-on components.
Screw out the bolt (A).

Detach the refrigerant lines (B, C) from the connections at the condenser.
Seal open connections at the lines and the connections at the condenser.
Note
- Seal open line connections at the connection point with clean plugs for example from the engine bung set VAS 6122.

Attach in reverse order, paying attention to the following:
Clean the refrigerant line connections at the condenser (C) and at the refrigerant lines (A, E) and check for damage.
Replace the O-rings (B, D), for version, refer to Electronic parts catalogue.
Check the fitted pin (installed in the connection at the condenser or refrigerant line, not provided at all connections) for damage and proper attachment.
Note
- Observe fitting instructions for O-rings Chapter“Refrigerant circuit seals”.
- After attachment the refrigerant lines to the condenser, check the routing of the refrigerant lines; they must be inserted in the brackets provided and should not make contact with other components.
Moisten the O-rings (B, D) slightly with refrigeration oil before fitting Chapter“Refrigerant circuit seals”.
Pay attention to correct positioning of the O-rings at the refrigerant lines ( A, E).
Insert the refrigerant lines (A, E) in the connections at the condenser.
Insert and tighten bolt (F).
- Tightening torque for bolt (F) with “M6” thread: 9 Nm
Following attachment, check the routing of the refrigerant lines. Ensure strain-free insertion in the holders provided and make sure the lines do not come into contact with other components.
Evacuate and charge the refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.
Re-install remaining components (removed earlier).
Interrogate the event memory of the front air conditioner operating and display unit E87 and erase any faults displayed Vehicle diagnostic tester“Guided fault-finding” mode.
Start up the air conditioner after charging the refrigerant circuit Chapter“Starting up air conditioner after charging refrigerant circuit”.
Note
- Also heed the information on start-up of the air conditioner after charging Air conditioner with refrigerant R134aRep. gr.87General information on air conditioner.
Parts & tools for this job For 2015 Audi A4
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A4 2015 cabin filter
As an Amazon Associate we earn from qualifying purchases.