Electrical system, self-diagnosisFault tables
Fault tables
Note
- Faults occurring in monitored sensors or components are stored in fault memory together with an indication of the type of fault.
- The fault tables are arranged according to the 5-digit fault codes in the left-hand column.
- Faults relating to the instrument cluster may also be displayed since the immobilizer is integrated into the instrument cluster.
- The fault memory records all static and sporadic faults. If a fault occurs and persists for at least 2 seconds, it is identified as a static fault. If a fault then no longer occurs, it is stored as “sporadic”. “Sporadic” additionally appears on the display.
- After switching on the ignition, all existing faults are set to “sporadic” and only stored as static if they still exist after checking.
- Sporadic faults which do not re-occur in the course of 50 driving cycles (ignition switched on for at least 5 minutes, vehicle speed greater than 30 km/h) are erased.
- Please do not immediately renew components indicated as faulty by the VAS 5051; first check the wiring and connectors of these components according to the current flow diagram. Also check the earth connections against the current flow diagram. This is particularly important in the case of “sporadic” faults.
- On completion of repair work, interrogate fault memory again and erase.
- After performing repairs, additionally interrogate the fault memory of the engine control unit and erase the entry “Engine control unit disabled”. Check other faults stored and eliminate if necessary.
| Display on VAS 5051 | Possible cause of fault | Fault elimination |
|---|---|---|
| 01128 Immobilizer reader coil D2 | Connector not plugged in or fault in reading coil/wiring | Check (visually inspect) connector and reading coil/wiring and renew reading coil if necessary Rep. Gr.96 |
| Immobilizer control unit (integrated into instrument cluster) defective | Erase fault memory → Chapter and interrogate again → Chapter; renew instrument cluster if necessary Rep. Gr.90 |
| Display on VAS 5051 | Possible cause of fault | Fault elimination |
|---|---|---|
| 01176 KeySignal too small | Fault in reading coil or wiring (contact resistance/loose contact) | Check (visually inspect) reading coil/wiring and connector and renew reading coil if necessary Rep. Gr.96 |
| No or defective electronics in ignition key (transponder) | Replace ignition key, re-match all ignition keys and check function → Chapter | |
| Not authorized | Mechanically correct ignition key not matched | Re-match all ignition keys and check function → Chapter |
| Display on VAS 5051 | Possible cause of fault | Fault elimination |
|---|---|---|
| 01177 Engine control unit Not authorised | Engine control unit not matched | Match engine control unit → Chapter |
| Open circuit or short to earth/positive in W-wire | Use current flow diagram to check wiring and connectors |
| Display on VAS 5051 | Possible cause of fault | Fault elimination |
|---|---|---|
| 01179 Key programming not OK | Ignition keys not properly matched | Re-match all ignition keys and check function → Chapter |
| Display on VAS 5051 | Possible cause of fault | Fault elimination |
|---|---|---|
| 65535 Control unit defective | Instrument cluster defective | Renew instrument cluster Rep. Gr.90 |