Calibrating matrix LED headlights with headlight adjustment unit VAS 621001
- Make
- Audi
- Model
- A6 C7
- Year
- 2011–2018
- Section
- Headlights › Calibrating matrix LED headlights with headlight adjustment unit VAS 621001
Calibrating matrix LED headlights with headlight adjustment unit VAS 621001
Note
- The matrix LED headlights are calibrated with the vehicle diagnostic testerVehicle diagnostic tester.
- The dipped headlights are adjusted first in this procedure. Afterwards the matrix main beam function is calibrated.


Align VAS 621001 to centre of vehicle at a distance of (a) = 100 mm Operating instructions of VAS 621001.
Ensure that VAS 621001 is parallel with transverse axis of vehicle. To do so, adjust laser beam of VAS 621001 so it hits securing bolts for wing at front left and front right (arrows).

Move VAS 621001 in front of left headlight and perform parallel check again.
Warning Danger of dazzling other road users if headlight adjustment unit is not correctly aligned.
- Take special care to ensure that the headlight adjustment unit is aligned properly. Only after this has been done can you adjust the headlights so that other road users will not be dazzled.
Vehicle diagnostic tester is connected.
Select Diagnosis mode and start diagnosis.
Select Test plan tab.
Select Own test then the following options one after the other:
- Body
- Electrical system
- 01 - Self-diagnosis compatible systems
- 55 - Dynamic headlight range control (MxB) -J431
- 55 - Headlight range control, functions
- 55 - Basic setting matrix beam (Repair Group 94)
Further instructions are given by Vehicle diagnostic tester during calibration procedure. The dipped headlights must be adjusted first in this procedure → Chapter.
During the program, you will be prompted to determine/read off the angle of the inner edge of the segment in the left headlight in the headlight adjustment unit and to enter this into the tester.
Align light collector lens centrally with reference segment of headlight.
Press “§” button (arrow) in main menu of VAS 621001 to start measurement procedure.

Indicated on display:

Press button (arrow) twice and wait for a moment until light measurement is active.
Indicated on display:

Press button (arrow).
Wait for a moment until light measurement has been performed.
Indicated on display:

Enter angle (arrow) of inner edge of reference segment in vehicle diagnostic tester. If necessary, note "+/-" sign.
During the program, you will be prompted to determine/read off the angle of the inner edge of the segment in the right headlight in the headlight adjustment unit and to enter this into the tester.
Align VAS 621001 to centre of vehicle at a distance of (a) = 100 mm Operating instructions of VAS 621001.

Ensure that VAS 621001 is parallel with transverse axis of vehicle. To do so, adjust laser beam of VAS 621001 so it hits securing bolts for wing at front left and front right (arrows).

Move VAS 621001 in front of right headlight and perform parallel check again.
Align light collector lens centrally with reference segment of headlight.
Indicated on display:

Press button (arrow).
Wait for a moment until light measurement has been performed.
Indicated on display:

Enter angle (arrow) of inner edge of reference segment in vehicle diagnostic tester. If necessary, note "+/-" sign.
After completing calibration, read out event memory and deal with any faults that are present.
Parts & tools for this job For 2011 Audi A6
- PARTReplacement bulbsSearch: Audi A6 2011 bulbs
- TOOLDigital multimeterSearch: automotive digital multimeter
As an Amazon Associate we earn from qualifying purchases.