A7 Sportback (2010-2018): Heating and air conditioning: Auxiliary/supplementary heater
Engine
Transmission
Steering & suspension
Brakes
Heating & A/C
Electrical
Body & interior
Choose Sections to see everything in a chapter, or a chapter title to start at its first page.
Engine
Transmission
Steering and suspension
Brakes
Electrical
Heating and air conditioning
- 29Heating and air conditioning: Auxiliary/supplementary heaterHeating and air conditioning: Auxiliary/supplementary heater: Sections
General notes18 pages
- General notes
- Type plates
- Notes on operation of auxiliary/supplementary heater on vehicles with diesel engine
- Starting conditions for auxiliary/supplementary heater
- Notes on auxiliary/supplementary heater
- Operating sequence for auxiliary heater
- Operating sequence - switching on auxiliary heater
- Operating sequence - auxiliary heater heating mode
- Operating sequence - switching off auxiliary heater
- Operating sequence - auxiliary ventilation
- Measured values and components monitored during operating sequence
- Sequence with required heat output between 50 and 100 %
- Sequence with required heat output less than 50 %
- Checking operation of coolant shut-off valve
- Operation of heater coolant shut-off valve N279
- Activation of heater coolant shut-off valve N279
- Rules for cleanliness when working on the auxiliary/supplementary heater and fuel system
- Overview of components for auxiliary heater in vehicle
Auxiliary/supplementary heater29 pages
- Auxiliary/supplementary heater
- Overview of fitting locations - auxiliary/supplementary heater
- Exploded view - components inside auxiliary/supplementary heater
- Removing and installing auxiliary/supplementary heater
- Dismantling and assembling auxiliary/supplementary heater
- Dismantling and assembling auxiliary/supplementary heater
- Removing and installing auxiliary heater control unit J364
- Removing and installing glow plug for heater Q9
- Removing and installing fuel pre-heating heater element Z66
- Removing and installing combustion air blower V6
- Removing and installing burner element
- Removing and installing heat exchanger
- Removing and installing air intake silencer
- Removing and installing circulation pump V55
- Removing and installing exhaust system
- Removing and installing bracket for auxiliary/supplementary heater
- Removing and installing flame monitor G64
- Removing and installing temperature sensor G18
- Removing and installing temperature sensor 2 for supplementary and auxiliary heating G587
- Pin assignment for auxiliary/supplementary heater
- Checking electrical components on auxiliary/supplementary heater
- Checking activation and electrical connections of auxiliary/supplementary heater
- Preparation for checking components on auxiliary heater
- Checking glow plug for heater Q9
- Checking combustion air blower V6
- Checking flame monitor G64
- Checking temperature sensor G18
- Checking temperature sensor 2 for supplementary and auxiliary heating G587
- Checking fuel pre-heating heater element Z66
Fuel supply system21 pages
- Fuel supply system
- Overview of fitting locations - fuel supply system
- Overview of fitting locations - fuel supply system
- Overview of fitting locations - fuel supply system, metering pump V54
- Fuel take-off from fuel tank
- Fuel take-off from fuel tank
- Releasing quick-release coupling at fuel line for auxiliary heater at fuel delivery unit
- Fuel delivery unit in fuel tank
- Filling fuel line to metering pump V54 with fuel, bleeding
- Checking fuel delivery rate
- Test requirements
- Preparation
- Checking fuel delivery rate
- Removing and installing metering pump V54
- Releasing quick-release coupling at fuel line for auxiliary heater at metering pump V54
- Removing and installing metering pump V54
- Routing of fuel line to auxiliary heater
- Checking CO2 content in auxiliary heater exhaust gas
- Checking CO2 content in auxiliary heater exhaust gas
- Test requirements
- Checking CO2 content
Auxiliary/supplementary heater control6 pages
- Auxiliary/supplementary heater control
- Functional description
- Switching auxiliary/supplementary heater on and off
- Overview - activation of auxiliary heater with remote control
- Activation of auxiliary heater with remote control
- Switching auxiliary heating / auxiliary ventilation on and off via Multi Media Interface (MMI, control unit for front di
Further control components12 pages
- Further control components
- Removing and installing ambient temperature sensor
- Removing and installing remote control receiver for auxiliary heater R64
- Functional description of remote control for auxiliary/supplementary heater
- Switching on auxiliary heating/auxiliary ventilation with “Immediate on” function
- Switching off auxiliary heating / auxiliary ventilation via “Immediate on” function
- Switching on auxiliary heating / auxiliary ventilation via “Timer” function
- Switching off auxiliary heating / auxiliary ventilation with “Timer” function
- Remote control for auxiliary heater
- Display of fault conditions on remote control for auxiliary heater
- Renewing battery of remote control for auxiliary heater
- Adaption of remote control for auxiliary heater
Body