Checking CO2 content
- Make
- Audi
- Model
- A7 Sportback
- Year
- 2010–2018
- Section
- Fuel supply system › Checking CO2 content
Checking CO2 content
Special tools and workshop equipment requiredVehicle diagnostic testerExhaust emission test station VAS 6300Battery charger VAS 5903Requirements satisfied → Chapter
Connect battery charger.
Connect vehicle diagnostic tester to diagnostic connection in vehicle.
Note
- The Guided Fault Finding for the auxiliary heater can only be started with the ignition switched on (the data bus diagnostic interface J533 is only active when the ignition is on). After the auxiliary heater has switched to diagnosis mode, the Guided Fault Finding for the auxiliary heater can be continued even with the ignition switched off.
Select address word “Additional/auxiliary heater”Vehicle diagnostic tester (“Guided Fault Finding”).
Select function “Interrogate event memory”Vehicle diagnostic tester (“Guided Fault Finding”).
Erase event memory if necessary Vehicle diagnostic tester (“Guided Fault Finding”).
Check coding and correct if necessary Vehicle diagnostic tester (“Guided Fault Finding”).
Select function “Check CO2 content of exhaust gas” or “Basic setting”Vehicle diagnostic tester (“Guided Fault Finding”).
Note
- The following description corresponds to the Guided Fault Finding test sequence.
Switch on exhaust emission test station VAS 6300 and insert exhaust probe (B) in exhaust pipe (A) of auxiliary heater.

Note
- It is not necessary to remove the wheel housing liner and the wheel housing spoiler (front right).
- Hose (B) of exhaust probe must not prevent exhaust gas from leaving exhaust pipe (A) during check.
Warning When pulling out the exhaust probe, take care not to touch the exhaust probe of the exhaust emission test station VAS 6300 or the exhaust pipe as these become very hot.
Set air conditioner operating unit (Climatronic control unit J255) to maximum heat output (“HI” temperature setting).
Restrict fresh air blower speed by setting air conditioner operating unit (Climatronic control unit J255) to approx. 50 % of maximum fresh air blower speed.
- The auxiliary heater is switched on via the “Basic setting” function Vehicle diagnostic tester (“Guided Fault Finding”).
Note
- For notes on switching on the auxiliary heater via the “Basic setting” function, refer to e.g. the section “Checking CO2 content in exhaust gas” of Guided Fault Finding; please also note the display of the activation signals for the auxiliary heater (e.g. in “General function check” in Guided Fault Finding) Vehicle diagnostic tester (“Guided Fault Finding”).
Wait until auxiliary heater switches from starting to full load operation (auxiliary heater must be at full load approx. 4 minutes after it is switched on).
Note
- If the connector for the heater coolant shut-off valve N279 is unplugged, the engine is also heated up and the auxiliary heater runs longer at full load.
- With the “Basic setting” function, the auxiliary heater can be operated up to a coolant temperature of 110 °C and starting from the control interval is possible. The operating time is then restricted to a maximum of 10 minutes Vehicle diagnostic tester (“Guided Fault Finding”).
Wait at least four more minutes after the auxiliary heater has started running at full load.
Read off measured value for CO2 (carbon dioxide) content of exhaust gas from CO2 measuring instrument.
- 8 to 11 % by CO2 volume for vehicles with diesel engine
- 7.5 to 10.5 % by CO2 volume for vehicles with petrol engine
Note
- If measured value is in lower range (less than 9 % for diesel or less than 8.5 % for petrol), problems may occur with auxiliary heater combustion under unfavourable conditions, e.g. high vehicle speed with auxiliary heater switched on. Check fuel delivery rate of metering pump V54Chapter.
- If CO2 values displayed by measuring instrument only fluctuate slightly, calculate mean value from highest and lowest measured value.
- If the measured values displayed for CO2 fluctuate considerably (more than approx. + / - 0.6 % depending on the analyser), check the position of the measurement probe in the auxiliary heater exhaust pipe.
- The auxiliary heater is switched off via the “Basic setting” function after measurement is complete Vehicle diagnostic tester (“Guided Fault Finding”).
If applicable, plug connector back in at heater coolant shut-off valve N279.
Interrogate event memory and erase if necessary Vehicle diagnostic tester (“Guided Fault Finding”).
Check intake air noise insulation and auxiliary heater exhaust system for contamination or cross-sectional constriction; clean or renew these components if necessary → Chapter and → Chapter.
Check fuel delivery rate of metering pump V54Chapter.
If CO2 content of exhaust gas and fuel delivery rate of metering pump V54 are in lower specified range, renew metering pump V54Chapter.
Check intake air noise insulation and auxiliary heater exhaust system for contamination or cross-sectional constriction; clean or renew these components if necessary → Chapter and → Chapter.
Check combustion air blower V6Vehicle diagnostic tester (“Guided Fault Finding”) and → Chapter.
Check glow plug for heater Q9 and fuel pre-heating heater element Z66Vehicle diagnostic tester (“Guided Fault Finding”), Chapter and → Chapter.
Note
- If problems with auxiliary heater operation only occur when the engine is switched off and the fuel tank is less than half full, refer to Chapter“Fuel take-off from fuel tank”.
Parts & tools for this job For 2010 Audi A7
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A7 2010 cabin filter