Connect test box V.A.G 1598/31 to connectors of wiring harness with black covering for engine control unit J623 (in electronics box, left-side); the engine control unit should not be connected. Connect earth clip of test box to earth Motronic injection and ignition system (12-cyl.)Rep. Gr.24.
Use leads from adapter set V.A.G 1594 A to bridge contacts 1 and 46 at test box.
Switch on ignition.
The secondary air pump relay J299 in position (2a/2b) (in relay and fuse carrier, electronics box/plenum chamber) should pick up and the secondary air pump motor V101 should run.
Connect test box V.A.G 1598/31 to connectors of wiring harness with blue covering for engine control unit J624 (in electronics box, right-side); the engine control unit should not be connected. Connect earth clip of test box to earth Motronic injection and ignition system (12-cyl.)Rep. Gr.24.
Use leads from adapter set V.A.G 1594 A to bridge contacts 1 and 46 at test box.
Switch on ignition.
The secondary air pump relay 2 J545 in position (9) (in relay and fuse carrier, electronics box/plenum chamber) should pick up and the secondary air pump motor 2 V189 should run.Check voltage supply of secondary air pump relay → Chapter.
Check activation of secondary air pump relay → Chapter.
Check voltage supply of secondary air pump motor → Chapter.
Parts & tools for this job For 1994 Audi A8
- PARTEngine gasket setSearch: Audi A8 1994 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.