Test sequence
- Make
- Audi
- Model
- A8 D2
- Year
- 1994–2002
- Section
- Servicing valve gear › Test sequence
12-cylinder engine, mechanicsTest sequence
Test sequence
Perform measurement with roller rocker fingers and supporting elements removed. Axial bearing cap for appropriate camshaft remains attached.
Secure universal dial gauge bracket VW 387 with dial gauge to cylinder head.

Determine axial clearance.
Wear limit (axial clearance): 0.10 mm.Parts & tools for this job For 1994 Audi A8
- PARTEngine gasket setSearch: Audi A8 1994 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set