Test sequence
- Make
- Audi
- Model
- A8 D2
- Year
- 1994–2002
- Section
- Servicing valve gear › Test sequence
12-cylinder engine, mechanicsTest sequence
Test sequence

Insert valve into valve guide. Only insert inlet valve into inlet guide and exhaust valve into exhaust guide, as the stem diameters are different.
End of valve stem must be flush with valve guide.Determine amount of sideways play.
Wear limit (sideways play): 0.8 mm.If wear limit is exceeded:
Renew the cylinder head.
Parts & tools for this job For 1994 Audi A8