Removing and installing expansion valve (front)
- Make
- Audi
- Model
- A8 D4
- Year
- 2010–2017
- Section
- Refrigerant circuit › Removing and installing expansion valve (front)
Removing and installing expansion valve (front)
Note
- After the air conditioner compressor is switched off, it might take a relatively long period on this vehicle before the pressure in the high-pressure side drops (the expansion valve is cold and the pressure in the low-pressure side increases rapidly after the compressor is switched off, the expansion valve is closed and the refrigerant can flow to the low-pressure side only slowly). If the air conditioner compressor is switched on, the pressure in the low-pressure side drops, the expansion valve is opened and the refrigerant can flow to the low-pressure side.
Switch off ignition.
Discharge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.
Remove plenum chamber partition panel General body repairs, exteriorRep. gr.50Bulkhead; Exploded view - bulkhead.
Detach the refrigerant line from the front expansion valve and lay aside (do not remove) Chapter“Detaching refrigerant lines from front expansion valve/re-attaching”.
Remove bolts (A).

Detach expansion valve (B) from refrigerant lines to evaporator.
Note
- Seal open pipes and connections at evaporator with suitable caps (to prevent ingress of dirt and moisture).
Install in reverse order of removal; note the following:
Make sure that the support ring (E) is correctly positioned and check the socket in the back wall of the plenum chamber for damage and proper installation.

Note
- This illustration shows the connections to the evaporator with the expansion valve removed.
Clean the connecting pipes (C) and (E) to the evaporator as well as the connections at the expansion valve and check for damage.

Note
- There are different versions of the expansion valve (identical housing but different characteristic control curve); therefore it is important to observe the correct assignment Electronic parts catalogue.
- Observe fitting instructions for O-rings Chapter“Refrigerant circuit seals”.
Clean the refrigerant line connections at the expansion valve (A) and at the refrigerant lines (C) and (E) and check for damage.
Renew O-rings (B) and (F); for correct version refer to Electronic parts catalogue.
Lubricate O-rings lightly with refrigerant oil before installing Chapter“Refrigerant circuit seals”.
Pay attention to correct positioning of the mounting plate (D) on the connecting pipes (C) and (E) to the evaporator.
Tighten bolts (G).
Tightening torque: 10 NmAttach the refrigerant line to the expansion valve Chapter“Detaching refrigerant lines from front expansion valve/re-attaching”.
Evacuating and charging refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.
Re-install remaining components (removed earlier).
Interrogate the event recorder of the front air conditioner operating and display unit, Climatronic control unit J255 and erase any faults displayed Vehicle diagnostic tester in “Guided Fault Finding” mode.
Start up air conditioner after charging refrigerant circuit Chapter“Starting up air conditioner after charging refrigerant circuit”.
Note
- Also observe notes on starting up air conditioner after charging Air conditioner with refrigerant R134aRep. gr.87General information on air conditioner.
Parts & tools for this job For 2010 Audi A8
- PARTEngine gasket setSearch: Audi A8 2010 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set