Separating refrigerant lines from condenser/connecting
- Make
- Audi
- Model
- A8 D4
- Year
- 2010–2017
- Section
- Refrigerant circuit › Separating refrigerant lines from condenser/connecting
Separating refrigerant lines from condenser/connecting
Note
- There are different condenser versions depending on the vehicle model. Electronic parts catalogue
Switch off ignition.
Discharge refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.
Remove cover at the lock carrier General body repairs, exteriorRep. gr.63Front bumper; Removing and installing attachments.
Remove noise insulation at front General body repairs, exteriorRep. gr.66Noise insulation; Removing and installing noise insulation.
Vehicles with 8-cyl. TFSI engine: Remove front bumper cover General body repairs, exteriorRep. gr.63Front bumper; Removing and installing bumper cover
Unscrew bolts (A) and (B).

Unfasten the holder (F) for the refrigerant lines (C) and (D) from the front end module (G).
Detach the refrigerant lines (C) and (D) from the condenser (E).
Seal open connections at the lines and the connections at the condenser.
Note
- Seal the open pipes and connections at the condenser with suitable caps (to prevent the ingress of dirt and moisture).
Attach in reverse order; note the following:
Clean the refrigerant line connections at the condenser (E) and at the refrigerant lines (C) and (D) and check for damage.
Replace the O-rings (J) and (K); for version refer to Electronic parts catalogue.
Check the fitted pin (L) (installed in the connection at the condenser or refrigerant line, not provided at all connections) for damage and proper attachment.
Note
- Observe fitting instructions for O-rings Chapter“Refrigerant circuit seals”.
- After attachment the refrigerant lines to the condenser, check the routing of the refrigerant lines; they must be inserted in the brackets provided and should not make contact with other components.
Lightly lubricate O-rings (J) and (K) with refrigerant oil before fitting Chapter“Refrigerant circuit seals”.
Pay attention to correct positioning of the O-rings (J) and (K) in the grooves of the corresponding mount.
Fit and tighten the bolts (A), (B) and (H).
- Tightening torque for bolts (A) and (B) with “M6” thread: 10 Nm
- Tightening torque for bolts (A) and (B) with “M8” thread: 20 Nm
- Tightening torque for bolt (H) 5 Nm
Following attachment, check the routing of the refrigerant lines. Ensure strain-free insertion in the holders provided and make sure the lines do not come into contact with other components.
Fit the front bumper cover and the cover at the lock carrier General body repairs, exteriorRep. gr.63Front bumper; Exploded view - bumper cover.
Evacuating and charging refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit.
Re-install remaining components (removed earlier).
Interrogate the event recorder of the front air conditioner operating and display unit, Climatronic control unit J255 and erase any faults displayed Vehicle diagnostic tester in “Guided Fault Finding” mode.
Start up air conditioner after charging refrigerant circuit Chapter“Starting up air conditioner after charging refrigerant circuit”.
Note
- Also observe notes on starting up air conditioner after charging Air conditioner with refrigerant R134aRep. gr.87General information on air conditioner.
Parts & tools for this job For 2010 Audi A8
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Audi A8 2010 cabin filter