Disconnecting and connecting battery in luggage compartment
- Make
- Audi
- Model
- Q3 8U
- Year
- 2011–2018
- Section
- Battery › Disconnecting and connecting battery in luggage compartment
Disconnecting and connecting battery in luggage compartment
Warning Risk of accident.
- Contrary to the following description, the battery must be disconnected with the ignition SWITCHED ON when working on pyrotechnic components (e.g. airbags, belt tensioners).

Switch off ignition.
Versions equipped with ignition lock: Remove ignition key.
Remove luggage compartment floor panel.
On vehicles equipped with subwoofer: Unplug electrical connector (4), unscrew bolt (2) and remove subwoofer (3).
Remove moulded insert (1).
Remove nut (1) and detach earth cable (2) from stud.

To prevent contact terminal of earth cable from coming into contact with vehicle body and causing a short circuit, wrap insulating tape around contact terminal.
Note
- When connecting earth cable to earth point, make sure electrical connector is attached to battery monitor control unit J367.
- If electrical connector at battery monitor control unit J367 is not attached when connecting battery, make sure to wait 30 seconds before attaching electrical connector.
When connecting battery, attach earth cable to stud by hand and tighten nut.
The following measures are required after re-connecting the battery:
- Activate automatic open/close function of electric window regulators Owner's Manual for the vehicle.
- Interrogate event memories of all control units and erase “Low voltage” entry Vehicle diagnostic tester.
Note
- On vehicles without radio-controlled clock, it is necessary to set the date again if the battery is disconnected for a long period Vehicle diagnostic tester.
Vehicle diagnostic tester is connected.
Select Diagnosis mode and start diagnosis.
Select Test plan tab.
Select Own test then the following options one after the other:
- Body
- Electrical system
- 01 - Self-diagnosis compatible systems
- 17 - Dash panel insert, functions
- 17 - Set date
Further instructions are given by Vehicle diagnostic tester.
Note
- After reconnecting the voltage supply, it is possible that the ESP warning lamp will not go out until the vehicle has been driven several metres.
- Chapter“Exploded view - battery in luggage compartment”
Parts & tools for this job For 2011 Audi Q3
- TOOLBattery testerSearch: car battery tester
- TOOLDigital multimeterSearch: automotive digital multimeter
- TOOLBattery terminal cleanerSearch: battery terminal cleaner