Removing and installing battery in luggage compartment
- Make
- Audi
- Model
- Q3 8U
- Year
- 2011–2018
- Section
- Battery › Removing and installing battery in luggage compartment
Removing and installing battery in luggage compartment
Note
- If renewing battery, connect battery charger to provide back-up power supply Electrical system; General informationRep. gr.27Charging battery.

Switch off ignition.
Versions equipped with ignition lock: Remove ignition key.
Remove luggage compartment floor panel.
On vehicles equipped with subwoofer: Unplug electrical connector (4), unscrew bolt (2) and remove subwoofer (3).
Remove moulded insert (1).
Remove bolts (arrows).

If fitted, move electrical wiring harness (3) clear.
Detach battery cover (1).
Detach heat shield (2) from battery.
Pull off cover (8) over negative battery terminal.

Slacken off nut (1) several turns and disconnect battery clamp (2) of earth cable from negative battery terminal.
Pull off cover (5) over positive battery terminal.
Slacken off nut (3) several turns and disconnect battery clamp (4) of positive cable together with main fuse holder from positive battery terminal.
Remove bolt (6) on battery retainer plate (7).
Pull off hose (9) for central gas venting system.
Pull battery out of battery tray and lift out of luggage compartment.
Warning Observe environmental requirements.
- When disposing of used batteries, always observe the required disposal procedures for batteries and sulphuric acid Electrical system; General informationRep. gr.27Battery.
Note
- Only install maintenance-free batteries with the specifications “TL82506” (from December 1997 onwards) and “VW75073” (from August 2001 onwards).
- Batteries from the Audi parts range feature a base strip adapter for matching to different retainer flanges. The battery operating instructions give details of when and how to use the base strip adapter.
Insert battery in battery tray (1) so that battery base strip engages in retainer flanges (arrows) of battery tray.

Fit battery retainer plate (1).

Tighten bolt (2) for battery retainer plate.
Fit hose (6) for central gas venting system.
Connect up battery in the following sequence with ignition and electrical equipment switched off:
First connect battery clamp (4) of positive cable by hand to positive battery terminal “+” and tighten nut (3).
Close cover (5) over positive battery terminal.
Note
- If electrical connector (2) at battery monitor control unit J367(item 3) is not attached when connecting battery, make sure to wait 30 seconds before attaching electrical connector.

Attach battery clamp of earth cable to negative battery terminal “–” by hand and tighten nut (1).
Check that battery is firmly secured after installing.
Close cover over negative battery terminal.
If the battery is renewed, the new battery must be adapted Vehicle diagnostic tester.
Vehicle diagnostic tester is connected.
Select Diagnosis mode and start diagnosis.
Select Test plan tab.
Select Own test then the following options one after the other:
- Body
- Electrical system
- 27 - Starter, current supply
- Electrical components
- A - Adapt battery after replacing
Further instructions are given by Vehicle diagnostic tester.
The following measures are required after re-connecting the battery:
- Activate automatic open/close function of electric window regulators Owner's Manual for the vehicle.
- Interrogate event memories of all control units and erase “Low voltage” entry Vehicle diagnostic tester.
Note
- After reconnecting the voltage supply, it is possible that the ESP warning lamp will not go out until the vehicle has been driven several metres.
- Chapter“Exploded view - battery in luggage compartment”