Specified Values

‹› In the display fields, the measured values increase contrary to the output value and show, that both sensors in the air quality sensor (G238) are

working correctly and that the air quality sensor (G238) electronics evaluated the measured values correctly.

-

Wait a short period time (approximately. 1 minute, depending on amount of test gas flowing into the sensor).

-

Read the air quality sensor (G238) measured values.

Specified Values

‹› The measured values will return to the output values and by doing so, show that both sensors are working correctly, and that the sensor electronics

evaluated the measured values correctly.

‹› Due to changed pollution values, it is possible that different values can be displayed than those by the first measuring.

-

Read the display with the measured values for the A/C operating status (recirculation/fresh air operation).

Specified Values

‹› The display field will show that the A/C is working in the fresh air mode.

‹› If a different "fresh air operation" value is displayed in the measured values block, then a request for air recirculation is already present (for

example, manually set to maximum cooling or recirculation), select a mode which does not require air recirculation. 

‹› If is appears in the measured values block that the air quality sensor (G238) is already requesting automatic air recirculation, then, if necessary,

clean the plenum chamber or move the vehicle into an area where the air is cleaner. Refer to => Vehicle Diagnosis, Testing and Information
System VAS 5051 in "Guided Fault Finding" function. 

-

Allow a little bit of butane from the lighter to flow past -  B - from the top area - A - of the air quality sensor (G238).

-

Read the recirculation/fresh air mode display.

Specified Values

‹› In the measured values block, it will be displayed that a request for air recirculation is present and that the A/C system is working in the air

recirculation mode.

‹› If is shows in the measured values block that the air quality sensor (G238) has requested automatic air recirculation, this request will not be

performed based on a shut off requirement from the climatronic control module (J255), A/C control head. Repair cause for this switch off
condition. Refer to => Vehicle Diagnosis, Testing and Information System VAS 5051 in "Guided Fault Finding" function.

‹› In order to avoid frequent shifting of the recirculated air/fresh air doors and the recirculation doors, the requirement of the air quality sensor

(G238) for "Automatic air recirculation" mode remains for at least 25 seconds (minimum duration period), even if the pollutant concentration is so
far reduced that recirculated air mode is no longer necessary. 