Operation of heated windscreen
The heated windscreen control unit J505(A) is activated by the convenience system central control unit J393 in response to a request from the front air conditioner operating and display unit E87Vehicle diagnostic tester in “Guided Fault Finding” mode and Current flow diagrams, Electrical fault finding and Fitting locations.

Note
- J505(A) is installed under the right A-pillar trim Current flow diagrams, Electrical fault finding and Fitting locations.
Activation of the windscreen heating is requested by E87 (version (A) or (B)) under the following conditions (for exact description, refer to Owner's Manual and Owner's Manual for “Infotainment / MMI”):

- Every time the engine is started cold when the ambient temperature is below + 5ー C, the E87 is set to “Auto” mode and the function has not been deactivated using the MMI (Multi Media Interface) Owner's Manual and Owner's Manual for “Infotainment / MMI”. The temperature on E87 must be set so that the air conditioner is in heating mode, and the temperature measured by the front left chest vent temperature sensor G385 and front right chest vent temperature sensor G386 is less than +35 °C. The heating period depends on the ambient temperature (max. 6 minutes at -40 °C).
- If, on selection of “Defrost” mode on E87, the ambient temperature is less than + 5 C and the function has not been deactivated via the MMI (Multi Media Interface). Depending on the ambient temperature, the heating period is between 2 and 6 minutes. As long as the heated windscreen Z2 is activated, the lamp in the Defrost button flashes. Activation only takes place when the engine is running.
The heated windscreen control unit J505(A) switches on the heating for the heated windscreen Z2 if the following conditions are fulfilled:
- The E87 transmits the request for activation to the J393 and the J393 relays this request to the J505.
- The voltage at J505 is greater than 12.70 V.
- J505 is not overheated.
Note
- Depending on the vehicle model, it may be possible to deactivate the Z2 via a function on the MMI (Multi Media Interface) Owner's Manual and Operating Manual for “Infotainment / MMI”.
- The J505 is activated by the J393 via a data line. If a condition prevails in the J505 that prevents the windscreen heating from switching on, the J393 is notified via this data line. The J393 then relays the information that the windscreen heating does not switch on to the E87Vehicle diagnostic tester in “Guided Fault Finding” mode.
- The resistance of the conductive coating on the plastic foil (4) in the heated windscreen Z2 is approx. 1.9 ohms. A voltage greater than the voltage of the electrical system is required to achieve the maximum possible heat output of approx. 1000 W (watts) at the windscreen. The heated windscreen control unit J505 converts the voltage of the electrical system into a variable voltage of between 25 V and 48 V depending on the electrical system voltage. If the voltage at J505 is greater than 13.10 V, Z2 is activated with a voltage greater than 41 V (up to max. 48 V) Vehicle diagnostic tester in “Guided Fault Finding” mode.

- In principle, the heated windscreen (A) has the following structure: (1) outer pane, (2) plastic film, (3) electrical connections, (4) plastic film with electrically conductive layer and (5) inner pane.
- The heated windscreen (A) is connected to the J505 via the connector (B)Current flow diagrams, Electrical fault finding and Fitting locations.
- To prevent the electrical system from overloading, J505 regulates the heat output of the heated windscreen (approx. 200 W when the electrical system voltage is 12.70 V and with infinitely variable regulation up to 1000 W at 13.10 V). The J505 permits an increase in power output of max. 200 W per second to prevent a drop in the electrical system voltage when the heated windscreen is switched on.
- The J505 queries the resistance of the Z2 to prevent the Z2 from activating in the event of a short circuit or a line interruption. If the resistance measured is less than approx. 1.4 ohms (short circuit) or greater than approx. 3.4 ohms (open circuit or contact resistance), the J505 does not switch on the heating or switches it off Vehicle diagnostic tester in “Guided Fault Finding” mode.
- In the final control diagnosis the Z2 is only activated at temperatures in the passenger compartment of up 40°C. If the temperature is higher, the display of the fault reader will show e.g. “Function unknown” or “Function cannot be performed at present”Vehicle diagnostic tester in “Guided Fault Finding” mode.
- The activation function of the J505(A) can be tested using the multimeter V.A.G 1715, for example. To do so, place pick-up clamp of multimeter V.A.G 1715 on positive wire from J505 to Z2 and select the function “Measuring current with pick-up clamp” on the multimeter V.A.G 1715. The display on the multimeter V.A.G 1715 changes from approx. 0 A to greater than 7 A Current flow diagrams, Electrical fault finding and Fitting locations.