Workshop Manuals Factory service & repair Audi
01 Servicing 6-cylinder TDI engine, common rail (EA 897 Gen. I)02 6-cylinder TDI engine, 3.0 ltr. 4-valve common rail (EA 897 Gen. I)03 Fuel supply system, diesel engines04 6-cylinder direct injection engine with supercharger (3.0 ltr. 4-valve TFSI)05 Fuel supply system, petrol engines06 4-cylinder direct injection engine (1.8, 2.0 ltr. 4-valve TFSI - generation III)07 Technical data for engines08 Rear final drive 0D2, 0D3, 0DB09 8-speed automatic gearbox 0D510 8-speed automatic gearbox 0D711 Running gear: Specifications for testing the braking force (according to German legislation)12 Running gear: Trailer Operation Guide13 Running gear: Wheel/Tyre Guide14 Running gear, front-wheel drive and four-wheel drive15 Brake system16 Heating, air conditioning17 Heating and air conditioning: Auxiliary/supplementary heater18 Electrical: Communication19 Electrical system20 Electrical: Basic information on high-voltage vehicles21 General body repairs, interior22 General body repairs, exterior
Audi Q7 Mk2 (2015-2023)16 · Heating, air conditioning
16 · Heating & A/C

Discharging refrigerant circuit

Make
Audi
Model
Q7 Mk2
Year
2015–2023
Section
Repair notes › Discharging refrigerant circuit
Heating, air conditioningDischarging refrigerant circuit

Discharging refrigerant circuit

Air conditioner with refrigerant R134a

Refrigerant must not be allowed to escape into the environment; it should be extracted from the refrigerant circuit with a suction unit or an air conditioner service station. The extracted refrigerant must then either be re-processed on site or returned to the manufacturer for proper disposal (different or additional regulations may apply in other countries). For this reason, the vehicle must be taken to a workshop which is equipped with the necessary tools and at which the work can be performed by appropriately qualified personnel Air conditioner with refrigerant R134aRep. gr.87General information on air conditioner.

Reason:

If refrigerant R134a escapes into the earth's atmosphere, it contributes towards the greenhouse effect.

Note

  • Refrigerant R134a has far less of a greenhouse effect than R12.
  • Refrigerant R134a does not affect the earth's ozone layer (R134a is an HFC with no chlorine atoms). Depletion of the ozone layer in the upper atmosphere is only brought about by the splitting of carbon-chlorine bonds (as is the case, for example, with refrigerant R12).
  • To drain, evacuate and fill the refrigerant circuit on vehicles with high-voltage system (Audi Q7 e-tron), the valves in the refrigerant circuit that are operated electrically must be open. Activate and open valves via a routine stored in the thermal management control unit J1024Vehicle diagnostic tester in “Guided Fault Finding” mode.

Vehicles without high-voltage system

After draining the air conditioner, unplug the connector from the air conditioner compressor regulating valve N280 or from the high-pressure sender G65.

Reason:

The air conditioner compressor regulating valve N280 is then no longer activated and the compressor runs at idle. The design of the air conditioner compressor is such that lubrication of the air conditioner compressor components is provided by way of an internal oil circuit at idling speed (provided there is sufficient refrigerant oil in the air conditioner compressor).

Vehicles with high-voltage system (Audi Q7 e-tron)

Initiate the basic settings of the air conditioner via the thermal management control unit J1024 and use a routine stored there “Extract, evacuate and charge refrigerant circuit” to open the electrically operated valves Vehicle diagnostic tester in “Guided Fault Finding” mode.

Reason:

Various electrically operated valves and non-return valves are installed in the refrigerant circuit. These electrically operating valves are closed or open, depending on the air conditioner's most recent operating state (cooling the passenger compartment, cooling the high-voltage system components, or heat pump mode). If more than one electrically operated valve needs to be closed, the refrigerant circuit may no longer be able to be fully drained, evacuated or chargedChapter“System overview - refrigerant circuit on vehicles with high-voltage system (Audi Q7 e-tron)” and Vehicle diagnostic tester in “Guided Fault Finding” mode

Parts & tools for this job For 2015 Audi Q7

As an Amazon Associate we earn from qualifying purchases.