audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Front Condensation Water Drain Hose, Checking, Removing and Installing|Page 15052 > < Front Condensation Water Drain Hose, Checking, Removing and Installing
Page 2
background image

-

Flap - D - can also be checked via the engine compartment (from above or below) with engine installed, depending on version.

-

For complaints of moisture in passenger compartment, check the following components as well as condensation water drains:
-

Water drain openings in plenum chamber.

-

Water drain from fresh air intake shaft.

-

Plenum chamber cover and wind cowl for damage and correct installation.

-

Dust and pollen filter for soiling and correct installation.

-

Forced air extraction vents in luggage compartment.

-

Actuation and function of fresh/recirculating air flap (visual inspection e.g. under instrument panel with cover removed) (and also via the
"output Diagnostic Test Mode (DTM)" function on vehicles with "Comfort" version A/C system, if necessary) Vehicle Diagnosis, Testing and
Information System VAS5051 in the "Guided Fault Finding" function.

-

Signal detecting windshield wiper operation at front A/C control head Climatronic Control Module J255 (e.g. via the "Read measuring value
block" function on vehicles with "Comfort" version A/C system) Vehicle Diagnosis, Testing and Information System VAS5051 in the "Guided
Fault Finding" function.

-

Check air outlet temperature from evaporator via measured values of Evaporator Vent Temperature Sensor G263 under the operating conditions
indicated by customer with the following setting on A/C control head Climatronic Control Module J255 (e.g. via the "Read measuring value
block" function) Vehicle Diagnosis, Testing and Information System VAS5051 in the "Guided Fault Finding" function.
-

Temperature preselect "Lo" for drivers and front passengers side (on "Comfort" version) or temperature switch at "Cold" stop (on "Basic"
version)

-

Intermediate fresh air blower speed (approx. 7 volts) Vehicle Diagnosis, Testing and Information System VAS5051 in the "Guided Fault
Finding" function.

-

Operating mode "Fresh Air".

-

Check measured value of Evaporator Vent Temperature Sensor G263 (e.g. via the "Read measuring value block" function) Vehicle Diagnosis,
Testing and Information System VAS5051 in the "Guided Fault Finding" function. If measured value is too low (at an ambient temperature
above 0 degree C, colder than 0 degree C for extended period of time) or too high (greater than e.g. 10 degrees C even though A/C system is
operating without problems), observe notes for testing cooling output and Vehicle Diagnosis, Testing and Information System VAS5051 in the
"Guided Fault Finding" function.

Removing 

-

Remove instrument panel trim under glove compartment.

-

Remove lower right "A" pillar trim.

-

If necessary, carefully fold back floor mat far enough that condensation water drain hose - A - is visible.

-

Cover area of floor mat under condensation water drain hose - A - with absorbent paper (so that any water present does not flow on to or below
floor mat).

-

Remove condensation water drain hose - A -.

Installing 

-

Check the following before installing condensation water drain hose - A - :

Front Condensation Water Drain Hose, Checking, Removing and Installing|Page 15052 > < Front Condensation Water Drain Hose, Checking, Removing and Installing