audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Refrigerant Lines, Disconnecting and Reconnecting At Rear Expansion Valve|Page 15076 > < Refrigerant Lines, Disconnecting and Reconnecting At Rear Expansion Valve|Page 15074
Page 2
background image

-

Pull off expansion valve - 2 -.

‹› Seal all open lines and connections on evaporator with suitable caps (to protect from damaged and avoid dirt and moisture from entering the

system). 

Installing

Installation is the reverse of removal, noting the following:

-

Replace O-ring seals - 4 - and - 5 -. 

-

Make sure that O-ring seals - 4 - and -  - are properly seated on connecting pipes to evaporator.

‹› Expansion valve is available in different versions (same housing but a different control characteristic), therefore ensure the exact allocation.

‹› Coat O-ring seals lightly with refrigerant oil before installing => [ O-Ring Seals for Refrigerant Circuit ] See: Service and Repair/Removal and

Replacement/O-Ring Seals for Refrigerant Circuit.

‹› If heat insulation is applied on the expansion valve (not intended at this time), a reduction in performance may arise when heat insulation is

missing or not installed correctly (modifies the set control characteristic by radiating heat).

‹› Retaining plate - 3 - is installed on connection pipes, check for proper fit when installing expansion valve.

-

Place expansion valve - 2 - on to connections on evaporator.

-

Install bolts - 1 - (tightening torque 10 Nm).

-

Replace O-rings - D - and - E -.

Refrigerant Lines, Disconnecting and Reconnecting At Rear Expansion Valve|Page 15076 > < Refrigerant Lines, Disconnecting and Reconnecting At Rear Expansion Valve|Page 15074