Removing and installing reservoir
Note
- Adjustment of the oil quantity depends on the nature of the problem.
- If, for example, the reservoir has been damaged in an accident (no loss of refrigerant, no ingress of moisture and dirt into the refrigerant circuit), the air conditioner can be serviced by weighing the old and new reservoir without the need for extensive repair work. Pour refrigeration oil into the new reservoir until it weighs the same as the reservoir removed Air conditioner with refrigerant R134aRep. gr.87General information on air conditioner (air conditioner with refrigerant R134a, general information on air conditioner).
- If an indeterminate amount of refrigeration oil has escaped or if dirt and moisture have ingressed into the refrigerant circuit, the refrigerant circuit must be cleaned Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (air conditioner with refrigerant R134a, refrigerant circuit, working with air conditioner service station).
- The following illustration shows the design of the refrigerant lines for an 8-cyl. engine. Vehicles with a 10-cyl. engine have an additional connection in the refrigerant lines to the reservoir) Electronic parts catalogue. Unfastening and fastening connections → Fig.

Detach the refrigerant lines (E and F) from the reservoir → Chapter.
Screw out the bolts (arrows).
Detach the reservoir (A) with the holder (G).
Slacken off the bolts (B) and pull the reservoir (A) out of the holder (G).
Tightening torque: Holder for reservoir to body 6 NmTightening torque: Refrigerant line to reservoir 9 NmInstall in reverse order, paying attention to the following:
Note
- The reservoir removed contains refrigeration oil, which must be returned to the refrigerant circuit (together with the new reservoir) Air conditioner with refrigerant R134aRep. gr.87Replacing refrigerant circuit components (air conditioner with refrigerant R134a, replacing refrigerant circuit components).
- Keep the reservoir closed for as long as possible, only remove the caps immediately before installation (the reservoir contains a desiccant bag which soon becomes saturated with moisture and hence unusable when the reservoir is open).
Insert the reservoir (A) in the holder (G).

Connect the refrigerant lines → Chapter.
On tightening the bolts (B) hold the reservoir such that there is no strain on the refrigerant lines (E and F).
Tighten the bolts (C and D).
Tightening torque: 9 Nm.Fit the rear left wheel housing liner Rep. gr.66.
Evacuate and charge the refrigerant circuit Air conditioner with refrigerant R134aRep. gr.87Refrigerant circuit (air conditioner with refrigerant R134a, refrigerant circuit, working with air conditioner service station).
On completion of repair work, perform the following operations on the operating unit, Climatronic control unit J255Vehicle diagnostic, testing and information system VAS 5051/, "Guided fault-finding" function:
Interrogate the event recorder and erase any faults displayed.
Start up the air conditioner after charging the refrigerant circuit → Chapter.
Note
- Also heed the information on start-up of the air conditioner after charging Air conditioner with refrigerant R134aRep. gr.87General information on air conditioner (air conditioner with refrigerant R134a, general information on air conditioner). Before starting up air conditioner after fresh charging.