Removing and installing battery
- Make
- Audi
- Model
- R8 Mk2
- Year
- 2015–2023
- Section
- Battery › Removing and installing battery
Removing and installing battery
Warning Risk of accident.
- Contrary to the following description, the battery must be disconnected with the ignition SWITCHED ON when working on pyrotechnic components (e.g. airbags, belt tensioners).
Note
- If renewing battery, connect battery charger to provide back-up power supply Electrical system; General informationRep. gr.27Charging battery.
Remove back panel trim in luggage compartment General body repairs, interiorRep. gr.70Luggage compartment trim panels; Overview of fitting locations - luggage compartment trim panels.
Remove luggage compartment floor and take out filler piece for warning triangle and first-aid kit General body repairs, interiorRep. gr.70Luggage compartment trim panels; Overview of fitting locations - luggage compartment trim panels.
Slacken off nut (4) several turns and disconnect battery clamp (3) of earth cable from battery terminal.

Slacken off nut (7) several turns and disconnect battery clamp (8) of positive cable from positive battery terminal.
Unscrew nut (5) and detach bracket (6).
Remove bolts (arrows) and detach battery base strip (1).
Lift battery (2) out.
Warning Observe environmental requirements.
- When disposing of used batteries, always observe the required disposal procedures for batteries and sulphuric acid Electrical system; General informationRep. gr.27Battery.
Note
- Only install maintenance-free batteries with the specifications “TL82506” (from December 1997 onwards) and “VW75073” (from August 2001 onwards).
- Batteries from the Audi parts range feature a base strip adapter for matching to different retainer flanges. The battery operating instructions give details of when and how to use the base strip adapter.
Slide battery into retaining brackets (1, 2) as far as stop, ensuring that battery base strip engages in retaining brackets.

Further installation is carried out in the reverse order; note the following:
Connect up battery in the following sequence with ignition and electrical equipment switched off:
First connect battery clamp of positive cable by hand to positive battery terminal “+” and tighten nut.
Unplug electrical connector (2) at battery monitor control unit J367(item 3).

Attach battery clamp of earth cable to negative battery terminal “–” by hand and tighten nut (1).
Reconnect connector at battery monitor control unit J367.
Check that battery is firmly secured after installing.
If the battery is renewed, the new battery must be adapted.
Connect vehicle diagnostic tester.
Select Diagnosis mode and start diagnosis.
Select Test plan tab.
Select Own test then the following options one after the other:
- Body
- Electrical system
- 01 - Self-diagnosis compatible systems
- 19 - Data bus diagnostic interface - J533
- 19 - Data bus diagnostic interface, functions
- 19 - Adaption
- 19 - Adapt battery
Start the program selected and follow the instructions on the display of the vehicle diagnostic tester.
The following measures are required after re-connecting the battery:
- Activate automatic open/close function of electric window regulators Owner's Manual for the vehicle.
- Interrogate event memories of all control units and erase “Low voltage” entry vehicle diagnostic tester.
Note
- After reconnecting the voltage supply, it is possible that the ESP warning lamp will not go out until the vehicle has been driven several metres.
- Chapter“Exploded view - battery”
Parts & tools for this job For 2015 Audi R8
- TOOLBattery testerSearch: car battery tester
- TOOLDigital multimeterSearch: automotive digital multimeter
- TOOLBattery terminal cleanerSearch: battery terminal cleaner
As an Amazon Associate we earn from qualifying purchases.