Check screw connection between filler neck and high pressure
non-return valve for leaks with leak tester spray.

Leak test:

If the leak test is O.K., a pressure test should then be carried out.

If a leak is detected during the leak test, tighten down the
appropriate screw connections on the clamping rings,

refer to section on opening/closing CNG-Swage-Lok connections.

Pressure test:

Disconnect test adapter 16 8 010.

Gas tank must be at least two thirds full. Connect special tool
13 8 010 to the diagnosis socket, switch on ignition and activate
the high-pressure non-return valve. Slowly opened gas cock on
gas tank.

Perform leak test with leak tester spray has in the leak test.

If the leak test is O.K., switch off ignition and disconnect special
tool 13 8 010.

If a leak pictures during the pressure test, tighten down the
appropriate clamping ring screw connections,

refer to section on Opening/closing CNG-Swage-Lok connection.

Then perform another pressure test. If there is still a leak, replace
the screw connection.

Caution!

Always remove special tool 13 8 010 before test runs to
avoid malfunctions.

RA  Checking CNG system for leaks and correct pressure (E34)

BMW AG - TIS

15.01.2013  13:15

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 4 -

10 RA Additional Work For CNG Vehicle (remove And Install Low-pressure And Metering Un > < 9 RA Checking CNG System For Leaks And Correct Pressure (E34)|Page 525