When tightening fuel injection lines, start at connection (4).

Note lines for cylinders 1,5,3,6,2,4 = firing sequence.

Note:

After assembly, longer starting time.

Turn engine on starter. The fuel delivery pump is activated by
the DDE control module, the fuel system thereby vents itself.

Installation:

Connect MoDiC or DIS to diagnosis jack, select diagnostic
program of DDE control module, select Special functions or
Test module, follow instructions on how to proceed. Read
fault memory of DDE control module, check stored fault
messages, rectify faults, clear fault memory.