bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

4 RA Checking Electr|Page 487 > < 3 RA Adjusting Injection Pump Statically (DDE 2) (M51)|Page 485
Page 1
background image

13 51 300

Checking electr. fuel cutoff unit (M51)

Connect up DIS or MoDiC and select diagnosis program of
DDE control unit, select component operation, then follow
instructions for subsequent procedure.

Remove protective cap (1).

The cutoff unit is supplied with power from ignition setting "Ignition
on" via the control unit. Switching-on will be heard by a loud click.

If a click is not heard, check power supply to the control unit.

For further tests, refer to BMW Diagnosis System.

Read out fault memory of DDE control unit.

RA  Checking electr. fuel cutoff unit (M51)

BMW AG - TIS

23.01.2013  06:57

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

4 RA Checking Electr|Page 487 > < 3 RA Adjusting Injection Pump Statically (DDE 2) (M51)|Page 485