Adjusting:

Loosen bolt (1).

Loosen nuts (1 and 2) - do not loosen them too far to prevent
torsion stress being applied by the chains.

Rotate injection pump until the dial gauge indicates the correct
value,

refer to Technical Data.

Tighten retaining points in sequence 1 ... 3.

Tightening Torque, refer to Technical Data.

Check setting once again.

Installation:

Connect DIS or MoDiC to the diagnosis receptacle, select
diagnosis program on the DDE control unit, interrogate fault
memory of DDE control unit, check fault messages stored in
memory, remedy faults and clear fault memory.

RA  Adjusting injection pump statically (DDE 2) (M51)

BMW AG - TIS

23.01.2013  06:57

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 3 -

4 RA Checking Electr > < 3 RA Adjusting Injection Pump Statically (DDE 2) (M51)|Page 484