bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

3 RA Adjusting Injection Pump Statically (DDE 2) (M51)|Page 485 > < 3 RA Adjusting Injection Pump Statically (DDE 2) (M51)
Page 2
background image

Rotate crankshaft clockwise towards the TDC setting of cylinder 1
(starting approx. 60 ... 90

°

 before this point) until the indicator

remains stationary for a short time at its lowest point. Set scale of
dial gauge to zero.

For inspection, 1st cylinder in TDC (working stroke):

Unscrew and remove oil filler cover.

1st cam on camshaft must point upwards.

Remove plug. Rotate crankshaft clockwise until the plug mandrel
(special tool 11 2 300) engages in the appropriate bore of the
flywheel.

Caution!

Do not rotate counter-enginewise - incorrect measuring result.

Read off stroke of distributor piston on dial gauge.

Note adjustment value, refer to Technical Data.

RA  Adjusting injection pump statically (DDE 2) (M51)

BMW AG - TIS

23.01.2013  06:57

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -

3 RA Adjusting Injection Pump Statically (DDE 2) (M51)|Page 485 > < 3 RA Adjusting Injection Pump Statically (DDE 2) (M51)