Unlock plug on pulse generator of left and right inlet camshafts and disconnect

Unlock plug on pulse generator of left and right exhaust camshafts and disconnect

Unlock plugs on both solenoid valves on left side and disconnect

Unlock plugs on both solenoid valves on right side and disconnect

Unlock plugs on left and right Valvetronic servomotors and disconnect

Unlock plugs on left and right eccentric shaft sensors and disconnect

Unlock plug on throttle valve potentiometer and disconnect

Unlock plug on differential pressure sensor and disconnect

Unlock plug on DISA servomotor and disconnect

Release negative lead on spring strut dome

Tightening torque 12 42 7AZ

.

Unlock plug connections in electronics box and disconnect:

at DME control unit

at Valvetronic control unit

at supply module

Do not remove control

units

Disconnect vent line

Release cable duct from intake manifold and remove wiring harness

Installation:

Now clear the fault memory.