2) Using a new gasket, attach crossover pipe to exhaust manifold and tighten bolts to 41 Nm (30 ft. lbs.) (Fig. 166).
3) Install the remaining manifold attaching bolts. Tighten all bolts to 23 Nm (200 inch lbs.).

4) Install and connect upstream oxygen sensor (Fig. 167).
5) Connect the spark plug wires to the spark plugs.
6) Connect the IAC,TPS and the EVAP hose to the throttle body
7) Install the air cleaner housing.
8) Raise the vehicle.
9) Attach catalytic converter pipe to exhaust manifold using new gasket and tighten bolts to 37 Nm (27 ft. lbs.).

10) Connect battery negative cable.