01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Rear seats19 Interior trim20 Electrical - general21 Starting and charging22 Wiring harnesses23 Instruments and warning lamps24 Locking, alarm and airbags25 Electrical - driver assistance systems26 Heating, air conditioning and audio
Citroën C3 Factory Workshop Manual (2002-2009)01 · Engine
01 · Engine

Removing - refitting: CNG injectors

Make
Citroën
Model
C3 Factory Workshop Manual
Year
2002–2009
Section
Air and fuel supply › Removing - refitting: CNG injectors
EngineRemoving - refitting: CNG injectors

Removing - refitting: CNG injectors

Citroën C3 · Removal-fitting · Ref. B1HGE8P0

Applies to: NVG dual fuel and 1.4i 75 (TU3JP)

ESSENTIAL: Observe the safety requirements that apply to repairs on CNG circuits (see the relevant operation).

ESSENTIAL: All work on a gas powered vehicle should be performed in a ventilated area.

1. Recommended tools

Figure e5ap2cfc

[2] hose clip pliers OETIKER (-).1615.

Figure e5ap1tjc

[2] union for venting fuel pressure 4192-T.

2. Removing

ESSENTIAL: De-pressurise the CNG supply circuit (see the relevant operation).

Disconnect the battery.

Figure b1bp3d7c

Disconnect the connectors at "a", "b", "c" and "d".

Cut the clip on the hose (1).

Uncouple the pipe (1).

Figure b1bp3d8c

Remove the air cleaner (4).

CAUTION: When connecting the tool [2], protect yourself with a cloth to guard against any projections of fuel.

The wiper arm nut (2).

Uncouple the fuel supply.

Release:

  • The seal (2)
  • The relay housing (3) with its support
Figure b1bp3d9c

Disconnect the connectors at "e", "f" and "g".

Uncouple:

  • The canister electrovalve (8) from its support
  • The oil vapour re-induction pipe (6)

Remove:

  • The mountings (7)
  • The compact coil housing (5)
Figure b1bp3dac

Remove:

  • The bolts (9)
  • The petrol injector rail (10)
Figure b1bp3dbc

Remove the 2 nuts (11).

CAUTION: Before removing, mark the positioning of the CNG connectors for each cylinder (colour markings).

Figure b1hp250c

Disconnect the connectors of the CNG injectors:

  • "H" Blue connector
  • "J" White connector
  • "K" Red connector
  • "L" Black connector
Figure b1bp3dcc

Remove:

  • The 5 bolts (14)
  • The air inlet manifold (13) and CNG injector distributor (12) assembly
Figure b1hp251d

Move aside the clip at "m" and remove the CNG injector (14) (following the arrow).

CAUTION: Do not damage the CNG injector.

Cut the clamping collar (15).

Uncouple the pipe (16).

Repeat the operation for the other CNG injectors.

3. Refitting

Couple the hose (16) to the CNG injector (14).

Fit new clips (15).

Tighten the clip (15) Using tool [1].

Figure b1hp252c

ESSENTIAL: Replace the seals (17) with new seals.

Move aside the clip at "m".

Fix the CNG injector (14) on the distributor (18) by rotating it.

CAUTION: Do not damage the seal (17).

Repeat the operation for the other CNG injectors.

Refit:

  • The air inlet manifold (13) and CNG injector distributor (12) assembly
  • The 5 bolts (14)
  • The 2 nuts (11)
Figure b1hp250c

Connect the connectors of the CNG injectors:

  • "H" Blue connector
  • "J" White connector
  • "K" Red connector
  • "L" Black connector

Refit:

  • The petrol injector rail (10)
  • The compact coil housing (5)
  • The canister electrovalve (8)

Connect the connectors at "e", "f" and "g".

Refit:

  • The oil vapour re-induction pipe (6)
  • The air cleaner (4)
  • The relay housing (3) with its support

Connect the connectors at "a", "b", "c" and "d".

Couple up:

  • The petrol supply
  • The hose (1) to the injector distributor

N.B.: Fit a new collar.

Tighten the clip on the hose (1) Using tool [1].

Reconnect the battery.

4. Additional operations

Re-pressurise the CNG supply circuit (see the relevant operation).

N.B.: Check the sealing at the clips (see the relevant operation).

Connect the diagnostic equipment to the vehicle’s diagnostic socket.

Start the vehicle.

Change to CNG mode.

Check:

  • That there are no faults
  • The CNG supply pressure (see the relevant operation)

Parts & tools for this job For 2002 Citroën C3