Removing - Refitting: Turbocharger cooling electric coolant pump
- Make
- Citroën
- Model
- C4 Factory Workshop Manual
- Year
- 2004–2010
- Section
- Cooling system › Removing - Refitting: Turbocharger cooling electric coolant pump
Removing - Refitting: Turbocharger cooling electric coolant pump
ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Location
(1) Turbocharger cooling electric coolant pump.
2. Removing
Disconnect the battery.
Remove the under engine protection.
Drain the cooling system.
Remove:
- The air deflector (5)
- The air resonator (6)
- The (2) bolt
- The turbo air supply union (3)
- The air entry union (4)
- The upper radiator hose (7)
Unclip and move aside the electrical harness (9) (as "a ", "b", "d").
Disconnect the connector (as "c").
Remove the clips (11), (13).
Disconnect the pipes (8), (12).
Remove:
- The bolts (10)
- The turbocharger cooling electric water pump (1) (With its mounting)
3. Refitting
Refit:
- The turbocharger cooling electric water pump (1) (With its mounting)
- The bolts (10)
Join the hoses (8), (12).
Refit the clips (11), (13).
Connect the connector (as "c").
Position and clip: The electrical harness (9) (as "a", "b", "d").
Refit:
- The upper radiator hose (7)
- The air entry union (4)
- The (2) bolt; Tighten to 0,8 ± 0,1 daN.m
- The turbo air supply union (3)
- The air resonator (6)
- The air deflector (5)
Reconnect the battery.
CAUTION: Perform the operations to be carried out following reconnection of the battery.
Fill and bleed the cooling system.
Refit the under-engine protection.
Parts & tools for this job For 2004 Citroën C4
- FLUIDCoolantSearch: Citroën coolant antifreeze
- PARTThermostatSearch: Citroën C4 2004 thermostat
- TOOLCooling system pressure testerSearch: cooling system pressure tester
As an Amazon Associate we earn from qualifying purchases.