Data: Cooling system (engine DV6TED4)
- Make
- Citroën
- Model
- C5 II Factory Workshop Manual
- Year
- 2004–2008
- Section
- Cooling system › Data: Cooling system (engine DV6TED4)
EngineData: Cooling system (engine DV6TED4)
Data: Cooling system (engine DV6TED4)
A: Version with neither thermoplungers nor additional heating.
B: Version with additional heating.
(1) bleed screw(s).
(2) Exhaust gas recycling (EGR) heat exchanger (version EURO 4).
(3) additional heating (according to equipment).
| Data (vehicle with or without air conditioning) | |
|---|---|
| Radiator surface area | 21 dm2 |
| Pressurisation | Cap with 1,4 bar rating |
| Opening of thermostatic regulator | 83 °C |
| Fan | With chopper control |
| Triggering threshold | 97 °C (stops at 94 °C) |
| Number x electrical power | 1 x 150 Watts |
| Air conditioning cut-off | 115 °C |
| Warning | 118 °C |
| Post-cooling | 105 °C (for 6 minutes) |
| Coolant temperature sensor located on the coolant outlet housing | Connector (green) |
| Engine coolant level sensor | Installed on the expansion chamber |
Parts & tools for this job For 2004 Citroën C5
- PARTEngine gasket setSearch: Citroën C5 2004 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.