Removing - refitting: Coolant outlet housing (DW12BTED4)
- Make
- Citroën
- Model
- C5 II Factory Workshop Manual
- Year
- 2004–2008
- Section
- Cooling system › Removing - refitting: Coolant outlet housing (DW12BTED4)
Removing - refitting: Coolant outlet housing (DW12BTED4)
ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Removing
ESSENTIAL: Respect the safety and cleanliness recommendations that are specific to high pressure diesel injection (HDi) engines.
Remove the engine style cover.
Disconnect the battery negative terminal.
Drain the cooling system (see the relevant operation).
Disconnect the connector "a".
Remove:
- The air filter (1) with the air flow sensor
- The air duct (2)
- The ECU carrier cover (3)
Detach and move aside:
- The pipe (4)
- The pipe (5)
Push into "b".
Uncouple the pipe (6).
Remove the clip (7).
Uncouple the pipe (8).
Remove:
- The nuts (9)
- The studs (10)
- The bolts (11)
- The pipe (13) fixing bolt and half moon (12)
Uncouple the coolant outlet housing (14) from the pipe (13).
Remove the coolant outlet housing (14) and its seal.
2. Refitting
Fit the coolant outlet elbow (14) with a new joint.
Couple the coolant outlet housing (14) to the pipe (13).
Refit the half moon and the bolt (12).
Refit:
- The studs (10); Tighten to 0,7 ± 0,1 daN.m
- The bolts (11); Tighten to 0,8 ± 0,1 daN.m
- The nuts (9); Tighten to 0,8 ± 0,1 daN.m
3. Refitting (continued)
Proceed in the reverse order to removal.
Fill and bleed the cooling system (see the relevant operation).
Parts & tools for this job For 2004 Citroën C5
- FLUIDCoolantSearch: Citroën coolant antifreeze
- PARTThermostatSearch: Citroën C5 2004 thermostat
- TOOLCooling system pressure testerSearch: cooling system pressure tester
As an Amazon Associate we earn from qualifying purchases.