Removing - refitting: EGR valves - EGR heat exchangers
- Make
- Citroën
- Model
- C6 Factory Workshop Manual
- Year
- 2005–2012
- Section
- Emission control › Removing - refitting: EGR valves - EGR heat exchangers
Removing - refitting: EGR valves - EGR heat exchangers
ESSENTIAL: Observe the safety and cleanliness recommendations.
CAUTION: Before disconnecting the battery, partially open the door windows.
ESSENTIAL: If raising the vehicle on a lift, wheels hanging, remove the cap of the LDS fluid reservoir. Refit the cap of the LDS fluid reservoir, once you have lowered the vehicle.
1. Recommended tools
[1] pliers to remove "clic" clips 4145-T.
2. Removing
ESSENTIAL: Respect the safety and cleanliness recommendations that are specific to high pressure diesel injection (HDi) engines.
Remove the engine style cover.
CAUTION: Keep the luggage compartment lid open.
Disconnect the battery.
2.1. EGR valve (front bank of cylinders)
Uncouple/move aside the pressure pipe of the steering assistance pump.
Disconnect the connector at " a ".
Remove:
- The mountings (7)
- The tube (1)
- The clip (8)
- The mountings (3)
- The tube (4)
- The mountings (6)
- The fixing (2)
Lift and move aside the EGR valve (10) and EGR heat exchanger (9) assembly.
Remove:
- The mountings (5)
- The EGR valve (10) and its seal
2.2. EGR heat exchanger (front bank of cylinders)
Drain the cooling system (see the relevant operation).
Remove the EGR valve (10) (see the relevant operation).
Disconnect the pipes At "b" and "c".
Remove the EGR heat exchanger (9).
2.3. EGR valve (rear bank of cylinders)
Disconnect the connector at " d ".
Remove:
- The mountings (13)
- The tube (14)
- The clip (12)
- The mountings (19)
- The tube (20)
- The mountings (16)
- The fixing (11)
Lift and move aside the EGR valve (15) and EGR heat exchanger (18) assembly.
Remove:
- The mountings (17)
- The EGR valve (15) and its seal
2.4. EGR heat exchanger (rear bank of cylinders)
Drain the cooling system (see the relevant operation).
Remove the EGR valve (15) (see the relevant operation).
Disconnect the pipes At "e" and "f".
Remove the EGR heat exchanger (18).
3. Refitting
3.1. EGR valve
Refit the EGR valve, with a new seal.
Proceed in the reverse order to removal.
3.2. EGR heat exchanger
Proceed in the reverse order to removal.
Refit the EGR valve, with a new seal.
Fill and bleed the cooling system (see the relevant operation).
Parts & tools for this job For 2005 Citroën C6
- PARTExhaust gasketSearch: Citroën C6 2005 exhaust gasket
- TOOLPenetrating oilSearch: penetrating oil
- TOOLOBD2 scannerSearch: OBD2 scanner
As an Amazon Associate we earn from qualifying purchases.