Removing - refitting: Oxygen sensor
- Make
- Citroën
- Model
- C6 Factory Workshop Manual
- Year
- 2005–2012
- Section
- Emission control › Removing - refitting: Oxygen sensor
Removing - refitting: Oxygen sensor
ESSENTIAL: Observe the safety and cleanliness recommendations.
CAUTION: For any operation on an oxygen sensor: The oxygen sensor connector must be cleaned dry. It is strictly prohibited to use solvents or contact greases for cleaning the connectors of the upstream and downstream oxygen sensors.
ESSENTIAL: If raising the vehicle on a lift, wheels hanging, remove the cap of the LDS fluid reservoir. Refit the cap of the LDS fluid reservoir, once you have lowered the vehicle (according to equipment).
CAUTION: Wait at least one hour before carrying out any work on the exhaust line.
1. Tooling
| Reference | Designation | Reference |
|---|---|---|
| [1] | [/] slit socket 22 mm | 4386-T |
2. Removing
Disconnect the connector of the oxygen sensor (1) (Front right wheel arch) (at "a").
Remove the oxygen sensor (1); Using tool [1].
3. Refitting
CAUTION: Adhere to the tightening torques.
Relocate: The oxygen sensor (1); Using tool [1].
Connect the connector of the oxygen sensor (1) (Front right wheel arch) (at "a").
Check all the equipment works.