ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Tooling
The filling operation can be carried out using approved coolant replacement equipment (Refer to the Garage Equipment catalogue). It is essential to follow the prescribed method of using the cylinder.
| Tools | References | Designation |
|---|---|---|
| [01102] | Tool for filling the cooling system by vacuum |
| [4520-T] | filling cylinder |
| [4222-T] | adaptor for filling cylinder |
| [4370-T] | blocking rod for filling cylinder |
| [0165-Z] | Pliers for removing elastic clips |
2. Preparation
To degas the low temperature cooling circuit and check the priming of the electric coolant pump, make the tool [1] using the following components:
- 1 Plug [1c] (Examples: Coolant outlet housing or low temperature radiator plug)
- 1 Transparent pipe [1a] (E.g.: Bleed pipe on fuel filter)
- 1 Plastic tie wrap [1b]
Forming of tool [1]: Fit the plug [1c] in the transparent pipe [1a]; Fix using the plastic tie wrap [1b].
3. Location
Combustion engine cooling circuit.
Low temperature cooling circuit (Hybrid drive train).
4. Drain and refill
4.1. Combustion engine cooling circuit
CAUTION: Do not operate on the engine when it is hot.
Put the vehicle on a hoist.
Remove the under engine protection.
CAUTION: Use a receptacle that is sufficiently large to take the totality of the coolant fluid.
Uncouple the engine cooling radiator lower hose (1); Using tool [0165-Z].
Allow the coolant to run out.
Remove the engine style cover.
Remove:
- The cap (2) of the expansion bottle
- The bleed plug (3)
N.B.: An additional quantity of fluid runs out.
Refit:
- The bleed plug (3)
- The bottom hose (1) of the radiator
CAUTION: Measure the quantity of coolant drained.
4.2. Low temperature cooling circuit (Hybrid drive train)
CAUTION: Do not operate on the engine when it is hot.
Put the vehicle on a hoist.
Remove the engine style cover.
Open the cap (2) of the header tank.
Raise the vehicle.
Remove:
- The nuts (4)
- The ventilation screen (5)
- The nut (6)
CAUTION: Use a receptacle that is sufficiently large to take the totality of the coolant fluid.
Uncouple the cooling circuit pipes (at "a").
Allow the coolant to run out.
Remove the bleed valve plug (7).
N.B.: An additional quantity of fluid runs out.
Refit the bleed valve plug (7).
N.B.: Wipe off the coolant on the heat shield.
Couple up the cooling circuit pipes (at "a").
Refit the nut (6).
CAUTION: Measure the quantity of coolant drained.
4.3. Complete cooling circuit
Drain:
- The internal combustion engine cooling circuit
- The low temperature cooling circuit (Hybrid drive train)
Raise the vehicle.
Uncouple a pipe from the cooling circuit (at "b").
CAUTION: Wear gloves and safety goggles; Risk of splashing.
Place a graduated receptacle on a component lift under the uncoupled pipe.
Drain the cooling circuit by means of a compressed air blower inserted in the union at "c".
N.B.: Take care to close all the plugs of the cooling circuit.
Couple up: The cooling circuit pipe (at "b").
CAUTION: Measure the quantity of coolant drained.
5. Refilling
CAUTION: Always use new coolant.
Return the vehicle to its wheels.
Put the equipment for filling by vacuum [01102] in place on the expansion bottle (at "d").
CAUTION: To avoid entry of air into the circuit, provide for 20 % additional coolant.
Prepare a receptacle of coolant containing the quantity of fluid drained + 20 %.
N.B.: The receptacle must be positioned slightly lower than the equipment for filling by vacuum.
Place the cooling circuit under a vacuum to reach -0,9 bar (at "A"):
- Wait 10 seconds and check that the value obtained does not drop
- Fill the cooling circuit completely and wait for the return to 0 bar (at "B")
N.B.: The quantity of coolant filled should correspond to the quantity of fluid drained.
Remove the equipment for filling by vacuum [01102] and rinse the assembly with clean water.
6. Bleeding
Fit the filling cylinder assembly [4520-T], the plug [4370-T] and the adapter [4222-T] to the filler opening.
Remove the bleed valve plug (at "f").
Position tool [1] in its place.
Fix the end of the pipe [1] in the filling cylinder [4520-T] (at "e").
Start the engine.
CAUTION: Check the flow of the fluid through the bleed pipe. The flow should begin after one minute maximum, otherwise stop the engine, check the electric coolant pump and fill the cooling circuit again (if necessary).
Keep the engine speed at 2500 rpm, up to the second cooling cycle (cooling fan(s) cutting in and out).
Stop the engine and wait for it to cool down.
7. Check
CAUTION: Do not operate on the engine when it is hot.
Open the bleed cap (7).
Check that there are no air bubbles.
N.B.: If there is an air bubble in the electric machine, start the filling procedure again.
Refit the bleed valve plug (7).
N.B.: Wipe off the coolant on the heat shield.
Remove the filling cylinder [4520-T], plug [4370-T] and adapter [4222-T] assembly.
Remove the tool [1].
Refit the bleed valve plug (at "f").
CAUTION: The level has to be up to the "maximum" mark on the degassing tank.
If necessary, top up the level in the header tank up to the maximum mark (engine cold).
Fit the degassing tank cap (2).
Check the absence of leaks.
Refit the engine style cover.
Refit (if necessary):
- The protective panel under the engine
- The ventilation screen (5)
- The nuts (4)
Parts & tools for this job For 2011 Citroën DS5