Workshop Manuals Factory service & repair Citroën
01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Rear seats19 Electrical - general20 Starting and charging21 Wiring harnesses22 Instruments and warning lamps23 Locking, alarm and airbags24 Electrical - driver assistance systems25 Heating, air conditioning and audio
Citroën DS5 Factory Workshop Manual (2011-2015)01 · Engine
01 · Engine

Dismantling - re-assembly: Variable timing electrovalve

Make
Citroën
Model
DS5 Factory Workshop Manual
Year
2011–2015
Section
Crankshaft › Dismantling - re-assembly: Variable timing electrovalve
EngineDismantling - re-assembly: Variable timing electrovalve

Dismantling - re-assembly: Variable timing electrovalve

Citroën DS5 · Removal-fitting · Ref. B1EG013BP0

Applies to: 1.6 thp 16v 200

ESSENTIAL: Observe the safety and cleanliness recommendations.

1. Location

Figure b1bg1csd

(1) Exhaust variable timing solenoid valve.

(2) Inlet variable timing solenoid valve.

(3) Eccentric shaft actuator.

2. Parts which must always be replaced

DesignationQuantity
Exhaust variable timing solenoid valve seal1
Inlet variable timing solenoid valve seal1
Eccentric shaft actuator seal1

3. Exhaust variable timing solenoid valve

3.1. Removing

ESSENTIAL: Allow the exhaust line to cool.

Disconnect the ancillaries battery.

Figure b1eg0jod

Disconnect the connector (as "a").

N.B.: Protect the surrounding area using a cloth on removal to absorb the oil which flows out of the opening.

Remove:

  • The (4) bolt
  • The (1) variable distribution solenoid valve

3.2. Refitting

CAUTION: Adhere to the tightening torques.

N.B.: Clean the sensor sealing zone and check that it is free of knocks and scratches.

Refit:

  • The (1) variable distribution solenoid valve   (equipped with a new seal)
  • The (4) bolt

Connect the connector (as "a").

CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.

Reconnect the ancillaries battery.

Check the oil level.

4. Inlet variable timing solenoid valve

4.1. Removing

Figure b1eg0y6d

Slacken the clip   (at "b").

Remove the bolts (9).

Unclip the air duct (5)   (pull downwards).

Remove:

  • The air ducts (5), (6)
  • The bolts (8)
  • The bracket (7)
Figure b1eg0jqd

Slacken the clip   (at "c").

Remove the air conduit (10).

Unclip and move aside: The fuel pipes (11)   (at "e").

N.B.: Check the presence of the diffuser   (at "d").

Figure b1eg0jrd

Unscrew:

  • The clips   (at "f", "h")
  • The lifting eye (12)

Disconnect the connector   (at "g").

Remove:

  • The bolts (14)
  • The air duct (13)
Figure b1eg0jsd

Disconnect the variable timing electrovalve connector (as "j").

Remove:

  • The (15) bolt
  • The (2) variable distribution solenoid valve

N.B.: Protect the surrounding area using a cloth on removal to absorb the oil which flows out of the opening.

4.2. Refitting

CAUTION: Adhere to the tightening torques.

N.B.: Clean the sealing zone of the electrovalve and check there are no signs of impact or scratching.

Refit:

  • The (2) variable distribution solenoid valve   (equipped with a new seal)
  • The (15) bolt

Reconnect connector of the variable timing electrovalve   (at "j").

Refit:

  • The air duct (13)
  • The bolts (14)

Tighten:

  • The lifting eye (12)
  • The clips   (at "f", "h")

Connect the connector   (at "g").

Reclip the fuel pipes (11)   (at "e").

Refit the air duct (10).

Tighten the clip   (at "c").

Refit:

  • The bracket (7)
  • The bolts (8)
  • The air ducts (5), (6)

Secure the air duct (5)   (towards the top).

Tighten the clip   (at "b").

Refit and tighten the screws (9).

CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.

Reconnect the ancillaries battery.

Check the oil level.

5. Eccentric shaft actuator

ESSENTIAL: Never supply the actuator directly: risk of injury. The actuator must only be supplied by the engine management ECU with the original connector, following correct fitting on the cylinder head.

5.1. Removing

Disconnect the ancillaries battery.

Figure b1bg1ctd

Remove:

  • The ancillaries battery cover (18)
  • The service battery
  • The engine cover (16)

Disconnect the connector   (at "m").

Disconnect the pipes (17), (19).

Remove:

  • The clips   (at "k", "l")
  • The air entry union (20)
Figure b1bg1cud

Disconnect the connector   (at "n").

Remove:

  • The resonator cover (28)
  • The resonator (27)
  • The clip   (at "p")
  • The (26) bolt
  • The air inlet duct (29)
  • The ancillaries battery tray (25)
  • The bolts (24)
  • The air filter cover (23)
  • The filter element
  • The (21) bolt
  • The air filter housing (22)
Figure b1eg0jtd

Disconnect the eccentric shaft actuator connector   (at "q").

Release and move aside the electrical harness (31)   (at "s").

N.B.: Protect the surrounding area using a cloth on removal to absorb the oil which flows out of the opening.

Remove the bolts (30).

Rotate the shaft anticlockwise   (at "r"); Using a 4 six-sided wrench.

Remove the actuator (3).

5.2. Refitting

Figure b1eg0jud

CAUTION: Before fitting a new ring seal the seal faces and surfaces must have no trace of impact nor scratches.

Remove the seal (32); By means of a screwdriver.

N.B.: Lubricate the inner face of the seal (32) slightly.

Refit a new seal (32) by hand.

CAUTION: Check that the seal is fully in its housing.

CAUTION: Adhere to the tightening torques.

Refit the actuator (3) with care.

Rotate the shaft clockwise   (at "r"); Using a 4 six-sided wrench.

Check that the flange of the variable lift eccentric shaft actuator is against the cylinder head.

Tighten the bolts (30).

Figure b1eg0jvd

CAUTION: To guarantee that the flange of the variable lift eccentric shaft actuator is sealed, plug the shaft   (at "r")   Using an adhesive strip. (at "t").

Clip the electrical harness (31)   (at "s").

Connect the eccentric shaft actuator connector   (at "q").

Refit:

  • The air filter housing (22)
  • The (21) bolt
  • The filter element
  • The air filter cover (23)
  • The bolts (24)
  • The battery tray (25)
  • The air inlet duct (29)
  • The (26) bolt
  • The clip   (at "p")
  • The resonator (27)
  • The resonator cover (28)

Connect the connector   (at "n").

Refit:

  • The air entry union (20)
  • The clips   (at "k", "l")

Couple up the pipes (17), (19).

Connect the connector   (at "m").

Refit:

  • The engine cover (16)
  • The service battery
  • The ancillaries battery cover (18)

CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.

Reconnect the ancillaries battery.

Check the oil level.

Parts & tools for this job For 2011 Citroën DS5