Dismantling - re-assembly: Variable timing electrovalve
- Make
- Citroën
- Model
- DS5 Factory Workshop Manual
- Year
- 2011–2015
- Section
- Crankshaft › Dismantling - re-assembly: Variable timing electrovalve
Dismantling - re-assembly: Variable timing electrovalve
ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Location
(1) Exhaust variable timing solenoid valve.
(2) Inlet variable timing solenoid valve.
(3) Eccentric shaft actuator.
2. Parts which must always be replaced
| Designation | Quantity |
|---|---|
| Exhaust variable timing solenoid valve seal | 1 |
| Inlet variable timing solenoid valve seal | 1 |
| Eccentric shaft actuator seal | 1 |
3. Exhaust variable timing solenoid valve
3.1. Removing
ESSENTIAL: Allow the exhaust line to cool.
Disconnect the ancillaries battery.
Disconnect the connector (as "a").
N.B.: Protect the surrounding area using a cloth on removal to absorb the oil which flows out of the opening.
Remove:
- The (4) bolt
- The (1) variable distribution solenoid valve
3.2. Refitting
CAUTION: Adhere to the tightening torques.
N.B.: Clean the sensor sealing zone and check that it is free of knocks and scratches.
Refit:
- The (1) variable distribution solenoid valve (equipped with a new seal)
- The (4) bolt
Connect the connector (as "a").
CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.
Reconnect the ancillaries battery.
Check the oil level.
4. Inlet variable timing solenoid valve
4.1. Removing
Slacken the clip (at "b").
Remove the bolts (9).
Unclip the air duct (5) (pull downwards).
Remove:
- The air ducts (5), (6)
- The bolts (8)
- The bracket (7)
Slacken the clip (at "c").
Remove the air conduit (10).
Unclip and move aside: The fuel pipes (11) (at "e").
N.B.: Check the presence of the diffuser (at "d").
Unscrew:
- The clips (at "f", "h")
- The lifting eye (12)
Disconnect the connector (at "g").
Remove:
- The bolts (14)
- The air duct (13)
Disconnect the variable timing electrovalve connector (as "j").
Remove:
- The (15) bolt
- The (2) variable distribution solenoid valve
N.B.: Protect the surrounding area using a cloth on removal to absorb the oil which flows out of the opening.
4.2. Refitting
CAUTION: Adhere to the tightening torques.
N.B.: Clean the sealing zone of the electrovalve and check there are no signs of impact or scratching.
Refit:
- The (2) variable distribution solenoid valve (equipped with a new seal)
- The (15) bolt
Reconnect connector of the variable timing electrovalve (at "j").
Refit:
- The air duct (13)
- The bolts (14)
Tighten:
- The lifting eye (12)
- The clips (at "f", "h")
Connect the connector (at "g").
Reclip the fuel pipes (11) (at "e").
Refit the air duct (10).
Tighten the clip (at "c").
Refit:
- The bracket (7)
- The bolts (8)
- The air ducts (5), (6)
Secure the air duct (5) (towards the top).
Tighten the clip (at "b").
Refit and tighten the screws (9).
CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.
Reconnect the ancillaries battery.
Check the oil level.
5. Eccentric shaft actuator
ESSENTIAL: Never supply the actuator directly: risk of injury. The actuator must only be supplied by the engine management ECU with the original connector, following correct fitting on the cylinder head.
5.1. Removing
Disconnect the ancillaries battery.
Remove:
- The ancillaries battery cover (18)
- The service battery
- The engine cover (16)
Disconnect the connector (at "m").
Disconnect the pipes (17), (19).
Remove:
- The clips (at "k", "l")
- The air entry union (20)
Disconnect the connector (at "n").
Remove:
- The resonator cover (28)
- The resonator (27)
- The clip (at "p")
- The (26) bolt
- The air inlet duct (29)
- The ancillaries battery tray (25)
- The bolts (24)
- The air filter cover (23)
- The filter element
- The (21) bolt
- The air filter housing (22)
Disconnect the eccentric shaft actuator connector (at "q").
Release and move aside the electrical harness (31) (at "s").
N.B.: Protect the surrounding area using a cloth on removal to absorb the oil which flows out of the opening.
Remove the bolts (30).
Rotate the shaft anticlockwise (at "r"); Using a 4 six-sided wrench.
Remove the actuator (3).
5.2. Refitting
CAUTION: Before fitting a new ring seal the seal faces and surfaces must have no trace of impact nor scratches.
Remove the seal (32); By means of a screwdriver.
N.B.: Lubricate the inner face of the seal (32) slightly.
Refit a new seal (32) by hand.
CAUTION: Check that the seal is fully in its housing.
CAUTION: Adhere to the tightening torques.
Refit the actuator (3) with care.
Rotate the shaft clockwise (at "r"); Using a 4 six-sided wrench.
Check that the flange of the variable lift eccentric shaft actuator is against the cylinder head.
Tighten the bolts (30).
CAUTION: To guarantee that the flange of the variable lift eccentric shaft actuator is sealed, plug the shaft (at "r") Using an adhesive strip. (at "t").
Clip the electrical harness (31) (at "s").
Connect the eccentric shaft actuator connector (at "q").
Refit:
- The air filter housing (22)
- The (21) bolt
- The filter element
- The air filter cover (23)
- The bolts (24)
- The battery tray (25)
- The air inlet duct (29)
- The (26) bolt
- The clip (at "p")
- The resonator (27)
- The resonator cover (28)
Connect the connector (at "n").
Refit:
- The air entry union (20)
- The clips (at "k", "l")
Couple up the pipes (17), (19).
Connect the connector (at "m").
Refit:
- The engine cover (16)
- The service battery
- The ancillaries battery cover (18)
CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.
Reconnect the ancillaries battery.
Check the oil level.
Parts & tools for this job For 2011 Citroën DS5
- PARTEngine gasket setSearch: Citroën DS5 2011 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.