ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Preliminary operations
Depressurise the hydraulic circuit () Using the diagnostic equipment.
2. Tooling
[1] Guide pegs = 4 threaded rods:
- Diameter "A" M6
- "B" = 50mm length
3. Removing
Remove: Piloted manual gearbox ECU.
Remove the bolts (1).
Remove:
- The earth plate (3)
- The retaining plate (2)
CAUTION: Do not use tools; Remove the pressure sensor (4) by hand.
Remove the pressure sensor (4).
CAUTION: Take care not to allow impurities to get into the hydraulic circuit.
4. Refitting
CAUTION: Clean the surfaces thoroughly.
Refit the pressure sensor (4), respecting the direction of fitting (Flat at "a").
Replace the holding plate (2), respecting the direction of fitting (Lug at "b" on the outside and on top).
Refit the ground plate (3).
CAUTION: Replace the bolts (1).
Refit the bolts (1) (new).
CAUTION: Check the correct alignment of the pins at "c" of the electrovalves and also of the pressure sensor (4) before refitting the ECU.
Fit the guide pegs [1].
Replace the seal on the ECU.
N.B.: Position the thickest side of the seal on the ECU (the thinnest side must be in contact with the piloting actuator).
CAUTION: The ECU connection can only withstand one removal-refit. Replace the ECU in the case of a second removal-refit.
Refit the ECU by hand until it is in contact with the joint face.
5. Additional operations
Repressurise and bleed the hydraulic circuit; Using the diagnostic equipment.
Programme the value of the engine torque transmitted to the clutch.
Parts & tools for this job For 2011 Citroën DS5
- TOOLOBD2 scannerSearch: OBD2 scanner
- TOOLDigital multimeterSearch: automotive digital multimeter
- TOOLBack-probe test leadsSearch: back probe test leads