Charge: Starting battery
- Make
- Citroën
- Model
- Jumper III Factory Workshop Manual
- Year
- 2006–2017
- Section
- Air and fuel supply › Charge: Starting battery
Charge: Starting battery
New vehicles delivered to customers now have a hydrometer which permits direct displaying of the charge status.
1. Application
This procedure applies to all ready-to-use batteries.
They are fitted on new vehicles or sold as Replacement Parts (boutique, warehouse, gondola end…).
The batteries must guarantee quality and reliability which meet the requirements of our customers.
They are an addition to the new vehicle preparation ranges distributed for each model of the range.
2. Recommended tools
Approved charging equipment: See garage equipment catalogue or, failing this, obtain a limited voltage charger.
Approved battery cable.
3. General principles for charging batteries
Comply with the maximum voltage indications and the nominal current level in relation to the type and size of the battery:
- Never apply an excessive voltage or current
- Use a charger suited to the battery and the type of charge required
- Do not use a rapid charger or, if the charger has this function, use the normal charge function
- Check the condition of the battery
N.B.: The effectiveness of the charge depends on the condition of the battery.
4. Precautions to be taken
Do not charge:
- A faulty battery (White hydrometer)
- A battery coated with sulphate (Depositing of a superficial layer of lead sulphate on the plates)
- A warm battery (Risk of thermal racing and damage)
5. Charging procedure
5.1. Preliminary operations
Remove the battery (1) located underneath the passenger compartment floor.
CAUTION: If the hydrometer is white, the battery is faulty: Replace the battery.
Check the conformity of the battery:
- Sealing of the case
- Absence of electrolyte leaks
- Absence of apparent signs of impact or cracks
- Status of the hydrometer
N.B.: Date of manufacture (If the battery was manufactured more than 6 months ago: Replace the battery).
5.2. Charging
Follow the operating instructions given by the manufacturer of the charger.
Check the clamps and terminals are clean. If the terminals are covered with sulphate (whitish or greenish deposit), strip and clean them.
The recharging operation must be carried out in a ventilated environment away from naked flames or any sources of sparks to prevent any risk of explosion and fire.
Do not recharge a frozen battery; it must first be thawed out to prevent the risk of an explosion; if it has frozen, have the battery checked before recharging by a specialist; they will check that the internal components have not been damaged and that the casing is not cracked, which would mean that toxic and corrosive acid could leak.
In the case of batteries with topping of up of the electrolyte only:
- Connect the battery to the charger starting with the positive cable
- Check the level (15 mm above the plates) and top up with distilled water (if necessary)
CAUTION: In the case of batteries which do not require maintenance, removal of the caps and topping up with fluid is strictly prohibited.
5.3. Automatic charger
Use the normal charging programme (Rapid charging prohibited).
5.4. Charger with limited voltage
Adjust the charging current to 1/20 of the capacity (example: 45Ah provides a charging current of 2,25A) for a charging time of 6 to 12 hours.
5.5. Limited voltage charger
Charge with a voltage limited to 14,8 V for 12 hours with a current limited to 1/4 of the capacity.
5.6. Precautions to be taken (Battery charge)
Monitor the progress of the charge regularly, ensuring in particular that the battery does not get excessively warm or does not start to bubble.
When the charge is complete, first switch off the charger and then disconnect the battery.
6. Check following charging
Check the colour of the hydrometer:
- If it is green: The battery is correct
- Refit the battery on the vehicle
- If it is not green: An additional charge is necessary, until the hydrometer turns green, without exceeding the times defined
- After 2 unsuccessful charging cycles, the battery is faulty
- Replace the battery
7. Fast starting
Open the bonnet.
CAUTION: Scrupulously comply with the order of the following instructions.
Connect the red cable to the metal part of the positive terminal (+) (in "a") on the jump battery (2) (as "b").
Connect the black or green cable to the metal part of the negative terminal (-) (in "d") of the jump battery (2) (as "c").
Operate the starter; Let the engine turn over.
Wait until it returns to idle and disconnect the cables.
Parts & tools for this job For 2006 Citroën Jumper
- TOOLBattery testerSearch: car battery tester
- TOOLDigital multimeterSearch: automotive digital multimeter
- TOOLBattery terminal cleanerSearch: battery terminal cleaner
As an Amazon Associate we earn from qualifying purchases.