Partially switched off: Power circuit
- Make
- Citroën
- Model
- Saxo Factory Workshop Manual
- Year
- 1996–2004
- Section
- Engine assembly › Partially switched off: Power circuit
‹ Prev Cleaning: engineNext › Safety recommendations: Petrol/natural gas (CNG) dual fuel system (NVG dual fuel, TU3JP) (issue 01/2006)
EnginePartially switched off: Power circuit
Partially switched off: Power circuit
ESSENTIAL: With the charging lead disconnected, switch off and wait 30 seconds after the water pump has stopped.
1. Partially switched off
Rear battery pack.
Upper battery pack.
Remove:
- The circuit breaker (2)
- Fuse (1)
Wait 15 seconds after switching off the 120 V.
Disconnect the battery: 12 volts supply.
2. Restoring supply voltage to the power circuit
Reconnect the battery: 12 volts supply.
Refit:
- Fuse (1)
- The circuit breaker (2)
CAUTION: On switching on again, Read the fault codes.
Erase the fault codes (if necessary).
Road test.
Read the fault codes.
‹ Prev Cleaning: engineNext › Safety recommendations: Petrol/natural gas (CNG) dual fuel system (NVG dual fuel, TU3JP) (issue 01/2006)