Total switching off: Power circuit
ESSENTIAL: With the charging lead disconnected, switch off and wait 30 seconds after the water pump has stopped.
1. Switching off
Put the vehicle on a hoist.
1.1. Upper battery pack
Remove:
- The circuit breaker (2)
- Fuse (1)
1.2. Lower battery pack
Remove:
- The circuit breaker (4)
- Fuse (3)
1.3. Rear battery pack
Remove:
- The circuit breaker (5)
- Fuse (6)
Wait 15 seconds after switching off the 120 V.
Disconnect the battery: 12 volts supply.
2. Restoring supply voltage to the power circuit
Reconnect the battery: 12 volts supply.
Refit:
- Fuse (1, 3, 6)
- The circuit breaker (2, 4, 5)
CAUTION: On switching on again, Read the fault codes.
Erase the fault codes (if necessary).
Road test.
Read the fault codes.
‹ Prev Safety recommendations: Petrol/natural gas (CNG) dual fuel system (NVG dual fuel, TU3JP) (issue 08/2006)Next › Checking and adjusting values: TU1 engine type