Workshop Manuals Factory service & repair Citroën
01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Rear seats19 Interior trim20 Electrical - general21 Starting and charging22 Locking, alarm and airbags23 Electrical - driver assistance systems24 Heating, air conditioning and audio
Citroën Xsara Factory Workshop Manual (1997-2000)01 · Engine
01 · Engine

Drain and refill: LPG tank

Make
Citroën
Model
Xsara Factory Workshop Manual
Year
1997–2000
Section
Air and fuel supply › Drain and refill: LPG tank
EngineDrain and refill: LPG tank

Drain and refill: LPG tank

Citroën Xsara · Draining - filling - bleeding · Ref. B1HI02P0

Applies to: LPG + unleaded petrol and 1.8 i 16v 112

ESSENTIAL: Follow the safety instructions.

1. Recommended tools

Figure e5ap14tc

[1] gas burner.

Figure e5ap13yc

[2] gas burner adapter.

[3] Adapter on tank.

Figure e5ap08hc

[4] station for repressurising suspension spheres 4130-T.

Figure e5ap08jc

[5] mastic gun.

2. Removing

ESSENTIAL: Take the vehicle out of the workshop.

Figure b1hp0w7c

Remove:

  • The tank cover
  • The cover (1)

Disconnect the solenoid valve (2) (positive terminal).

Figure c4bp13lc

Connect the LPG tank to earth, as "a".

ESSENTIAL: Start the engine. Change to LPG mode. Wait until the engine stops due to lack of lpg. Switch off the ignition. Disconnect the battery (positive terminal).

Figure b1hp0x6d

Disconnect the tube (4) from the union (5).

Connect the gas burner [1] to the tank outlet using the connector tube (3) and adapters [2] and [3].

Keep the valve (6) in the "off" position.

Figure b1hp0y3c

ESSENTIAL: Position the gas burner [1] 20 m from any inflammable substances and as far away as possible from the vehicle.

Connect the gas burner [1] to earth, as "b".

Open the valve (6) slightly.

Connect the positive terminal of the electrovalve (2) to the positive terminal of the battery with a fly lead.

Bleed the gas burner [1] by opening the valve (10) slightly until tube (9) ices up then close the valve (10).

Bleed the pilot tube by opening the valve (7) by 1/4 of a turn (for 20 seconds).

Operate the electric ignition system (8): The flame should be 15 cm high.

Open the valve (10) by 3/4 turns.

Move away from the gas burner [1].

Open the valve (6) fully.

The flame should be 3 - 4 m high.

Should an operating problem occur: Close the valve (6).

Figure c4cp0mmc

Allow the gas to burn.

When the flame intensity decreases, Connect the tool [4] to the vehicle Using tool [5].

Send nitrogen to the LPG tank at a pressure of 4 bar.

When the flame extinguishes, Try to relight the burner several times, Using the electric ignition system.

When it is impossible to relight, Allow nitrogen to escape through the gas burner for several minutes.

Disconnect:

  • The tool [3]
  • The tool [5]
  • The electrovalve (2) supply fly lead

Parts & tools for this job For 1997 Citroën Xsara

As an Amazon Associate we earn from qualifying purchases.