Checking-adjusting: Lpg feed pressure
- Make
- Citroën
- Model
- Xsara Factory Workshop Manual
- Year
- 1997–2000
- Section
- Engine assembly › Checking-adjusting: Lpg feed pressure
Checking-adjusting: Lpg feed pressure
ESSENTIAL: Before any operations Follow the safety instructions.
1. Recommended tools
[1] pressure checker (kit S.1602).
[2] pressure take-off connector (kit S.1602).
[3] hose for removing-fitting pressure connector (kit S.1602).
[4] LPG pressure adjusting knob 9603-T.
2. Checking and setting the pressure of the 1st stage
2.1. Preliminary operations
Start the engine.
Wait for the fan to engage and then disengage.
Change to LPG mode.
Remove:
- The tank cover
- The cover (1)
Disconnect the solenoid valve (2).
Wait until the engine stops due to lack of lpg.
Switch off the ignition.
Disconnect the battery.
Disconnect the solenoid valve (3).
Remove the plug (4).
Fit the tool [2] instead of and in place of the plug (4) Using tool [3].
Tighten the tool [2].
2.2. Checking-adjusting
Connect output "a" of tool [1] to tool [2].
Connect output "b" of tool [1] to take-off (5).
Reconnect:
- The solenoid valve (3)
- The solenoid valve (2)
- The battery
Start the engine.
Change to LPG mode.
Accelerate the engine: Up to 3000 rpm.
Return to idle.
Wait 30 seconds.
Read the pressure Using tool [1].
Adjustment values:
- Evaporator control valve which has already been used: 1400 ± 50 mb
- New evaporator control valve: 1450 ± 50 mb
Adjust the value of pressure by adjusting the screw (6) Using tool [4] (if necessary).
N.B.: Tighten the screw to increase the pressure. Slacken the screw to reduce the pressure.
2.3. Additional operations
Disconnect the solenoid valve (2).
Wait until the engine stops due to lack of lpg.
Switch off the ignition.
Disconnect:
- The battery
- The solenoid valve (3)
Remove:
- The tool [1]
- The tool [2] Using tool [3]
Refit and tighten the plug (4).
3. Checking and setting the pressure of the 2nd stage
3.1. Preliminary operations
Slacken the 2 fixing screws of the distributor (7).
Remove the 2 fixing screws.
Raise the distributor (7).
Remove the plug (8).
Fit the tool [2] Using tool [3].
Tighten the tool [2].
3.2. Checking-adjusting
Connect output "a" of tool [1] to tool [2].
Connect output "b" of tool [1] to take-off (5).
Reconnect:
- The solenoid valve (3)
- The solenoid valve (2)
- The battery
Start the engine.
Change to LPG mode.
Accelerate the engine: Up to 3000 rpm.
Return to idle.
Wait 30 seconds.
Read the pressure Using tool [1].
Adjustment values:
- Evaporator control valve which has already been used: 960 ± 10 mb
- New evaporator control valve: 970 ± 10 mb
Adjust the value of pressure by adjusting the screw (9) Using tool [4] (if necessary).
N.B.: Tighten the screw to increase the pressure. Slacken the screw to reduce the pressure.
3.3. Additional operations
Disconnect the solenoid valve (2).
Wait until the engine stops due to lack of lpg.
Switch off the ignition.
Disconnect the battery.
Remove:
- The tool [1]
- The tool [2] Using tool [3]
Refit and tighten the plug (8).
Fit the distributor (7).
Reinstall the 2 fixing screws.
Tighten the 2 mounting bolts of the distributor (7).
Reconnect:
- The solenoid valve (3)
- The battery
Start the engine.
Check that the lpg mode operates correctly.
Refit:
- The cover (1)
- The tank cover