Stratus Coupe V6-3.0L VIN H (2001)
Washer Fluid Level Switch Input Circuit
Connectors
CIRCUIT OPERATION
The ETACS-ECU operates the low washer fluid level warning light according to the input signal from the washer fluid level switch.
TECHNICAL DESCRIPTION (COMMENT)
The washer fluid level switch input signal is used to operate the following functions:
-
Low washer fluid level tone alarm function
-
Low washer fluid level warning light
If the signal fails, these devices will not work normally.
TROUBLESHOOTING HINTS
-
Malfunction of the washer fluid level switch