Fault diagnosisStarter motor not working
STARTER MOTOR NOT WORKING
When the key is turned to the On position the instruments light up, but the starter motor does not turn
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
| Place the key in the ON position and check that the recharging warning light comes on (it should then go out when the engine is started up). | Continue to Step 1 | The recharging warning light does not come on | See table K40 BATTERY CHARGING WARNING LIGHT NOT WORKING | |
| 1 | STARTER MOTOR CONNECTIONS CHECK | All OK | Problems met | Operation |
| Check the connections between the battery, alternator and starter motor See E5010 STARTING AND RECHARING | Continue to Step 2 | Connections not correct | Restore the battery connections See E5010 STARTING AND RECHARING | |
| Damaged earth lead | Replace the cable Op. 5530B22 | |||
| Cable between the battery and the starter motor. | Replace the cable Op. 5530B26 | |||
| 2 | CHECK IGNITION SWITCH | All OK | Problems met | Operation |
| Check condition and correct operation of ignition switch. | Continue to Step 3 | Ignition switch faulty | Renew or replace the ignition switch Op. 5520A12 | |
| 3 | STARTER MOTOR CHECK | All OK | Problems met | Operation |
| Check condition and correct operation of starter motor. | Continue to Step 4 | Starter motor faulty | Overhaul the starter motor Op. 5520B14 | |
| Unrepairable starter motor fault | Replace the starter motor Op. 5520B10 | |||
| 4 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | Fault persists | Search for the fault starting from another symptom' | ||
When the key is turned to the On position the instruments light up, but the starter motor does not turn
| Results of the tests | ||||
| 0 | PRELIMINARY CHECKS | All OK | Problems met | Operation |
|---|---|---|---|---|
| Place the key in the ON position and check that the recharging warning light comes on (it should then go out when the engine is started up). | Continue to Step 1 | The recharging warning light does not come on | See table K40 BATTERY CHARGING WARNING LIGHT NOT WORKING | |
| 1 | STARTER MOTOR CONNECTIONS CHECK | All OK | Problems met | Operation |
| Check the connections between the battery, alternator and starter motor See E5010 STARTING AND RECHARING | Continue to Step 2 | Connections not correct | Restore the battery connections See E5010 STARTING AND RECHARING | |
| Damaged earth lead | Replace the cable Op. 5530B22 | |||
| Cable between the battery and the starter motor. | Replace the cable Op. 5530B26 | |||
| 2 | CHECK IGNITION SWITCH | All OK | Problems met | Operation |
| Check condition and correct operation of ignition switch. | Continue to Step 3 | Ignition switch faulty | Renew or replace the ignition switch Op. 5520A12 | |
| 3 | STARTER MOTOR CHECK | All OK | Problems met | Operation |
| Check condition and correct operation of starter motor. | Continue to Step 4 | Starter motor faulty | Overhaul the starter motor Op. 5520B14 | |
| Unrepairable starter motor fault | Replace the starter motor Op. 5520B12 | |||
| 4 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | Fault persists | Search for the fault starting from another symptom' | ||
When the key is turned to the On position the instruments light up, but the starter motor does not turn
| Results of the tests | ||||
| 0 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
|---|---|---|---|---|
| Connect the diagnostic equipment (Examiner) and check battery charge | Continue to Step 2 | Battery charge status insufficient. | Recharge the battery Op. 5530B14 | |
| Battery flat and no longer rechargeable | Replace the battery Op. 5530B10 | |||
| 1 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation |
| Check continuity/insulation of electrical connection between starter motor and battery See E5010 STARTING AND RECHARING | Continue to Step 2 | Electrical connection interrupted or not insulated. | Restore electrical connection continuity/insulation See E5010 STARTING AND RECHARING | |
| 2 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation |
| Check continuity/insulation of ignition barrel and starter motor connection. See E5010 STARTING AND RECHARING | Continue to Step 3 | Electrical connection interrupted or not insulated. | Continue to Step 4 | |
| 3 | CHECKING IGNITION BARREL | All OK | Problems met | Operation |
| Check that the ignition barrel is working properly. | Continue to Step 7 | Ignition barrel damaged. | Change the ignition barrel Op. 5520A12 | |
| 4 | CHECKING ELECTRICAL CIRCUIT | All OK | Problems met | Operation |
| Check continuity/insulation of electrical connection between ignition block and engine bay control unit See E5010 STARTING AND RECHARING | Continue to Step 5 | Electrical connection interrupted or not insulated. | Restore electrical connection continuity/insulation See E5010 STARTING AND RECHARING | |
| 5 | CHECKING ELECTRICAL CIRCUIT | All OK | Problems met | Operation |
| Check continuity/insulation of electrical connection between engine bay control unit and starter motor See E5010 STARTING AND RECHARING | Continue to Step 6 | Electrical connection interrupted or not insulated. | Restore electrical connection continuity/insulation See E5010 STARTING AND RECHARING | |
| 6 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Change engine bay control unit Op. 5505A13 | |
| 7 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Replace the starter motor Op. 5520B10 | |
When the key is turned to the On position the instruments light up, but the starter motor does not turn
| Results of the tests | ||||
| 0 | CHECKING WITH DIAGNOSTIC EQUIPMENT | All OK | Problems met | Operation |
|---|---|---|---|---|
| Connect the diagnostic equipment (Examiner) and check battery charge | Continue to Step 2 | Battery charge status insufficient. | Recharge the battery Op. 5530B14 | |
| Battery flat and no longer rechargeable | Replace the battery Op. 5530B10 | |||
| 1 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation |
| Check continuity/insulation of electrical connection between starter motor and battery See E5010 STARTING AND RECHARING | Continue to Step 2 | Electrical connection interrupted or not insulated. | Restore electrical connection continuity/insulation See E5010 STARTING AND RECHARING | |
| 2 | ELECTRICAL CIRCUIT CHECK | All OK | Problems met | Operation |
| Check continuity/insulation of ignition barrel and starter motor connection. See E5010 STARTING AND RECHARING | Continue to Step 3 | Electrical connection interrupted or not insulated. | Continue to Step 4 | |
| 3 | CHECKING IGNITION BARREL | All OK | Problems met | Operation |
| Check that the ignition barrel is working properly. | Continue to Step 7 | Ignition barrel damaged. | Change the ignition barrel Op. 5520A12 | |
| 4 | CHECKING ELECTRICAL CIRCUIT | All OK | Problems met | Operation |
| Check continuity/insulation of electrical connection between ignition block and engine bay control unit See E5010 STARTING AND RECHARING | Continue to Step 5 | Electrical connection interrupted or not insulated. | Restore electrical connection continuity/insulation See E5010 STARTING AND RECHARING | |
| 5 | CHECKING ELECTRICAL CIRCUIT | All OK | Problems met | Operation |
| Check continuity/insulation of electrical connection between engine bay control unit and starter motor See E5010 STARTING AND RECHARING | Continue to Step 6 | Electrical connection interrupted or not insulated. | Restore electrical connection continuity/insulation See E5010 STARTING AND RECHARING | |
| 6 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Change engine bay control unit Op. 5505A13 | |
| 7 | CHECKING CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | Fault persists | Replace the starter motor Op. 5520B10 | |
Parts & tools for this job For 2000 Fiat Doblò
- TOOLBattery testerSearch: car battery tester
- TOOLDigital multimeterSearch: automotive digital multimeter
- TOOLBattery terminal cleanerSearch: battery terminal cleaner
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.