1. Application
- Make
- Fiat
- Model
- Ducato Mk3 (250) Factory Service Manual
- Year
- 2006–2017
- Section
- Starting battery: charge › 1. Application
New vehicles delivered to customers now have a hydrometer which permits direct displaying of the charge status.
1. Application
This procedure applies to all ready-to-use batteries.
They are fitted on new vehicles or sold as Replacement Parts (boutique, warehouse, gondola end… ).
The batteries must guarantee quality and reliability which meet the requirements of our customers.
They are an addition to the new vehicle preparation ranges distributed for each model of the range.
2. Recommended tools
Approved charging equipment : See garage equipment catalogue or, failing this, obtain a limited voltage charger.
Approved battery cable.
3. General principles for charging batteries
Comply with the maximum voltage indications and the nominal current level in relation to the type and size of the battery :
- Never apply an excessive voltage or current
- Use a charger suited to the battery and the type of charge required
- Do not use a rapid charger or, if the charger has this function, use the normal charge function
- Check the condition of the battery
N.B. : The effectiveness of the charge depends on the condition of the battery.
4. Precautions to be taken
Do not charge :
- A faulty battery (White hydrometer)
- A battery coated with sulphate (Depositing of a superficial layer of lead sulphate on the plates)
- A warm battery (Risk of thermal racing and damage)
5. Charging procedure
5.1. Preliminary operations
Parts & tools for this job For 2006 Fiat Ducato
- TOOLBattery testerSearch: car battery tester
- TOOLDigital multimeterSearch: automotive digital multimeter
- TOOLBattery terminal cleanerSearch: battery terminal cleaner
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.