ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 9276 > < Initial Inspection and Diagnostic Overview|Page 9274
Page 11
background image

YES

GO to B1322-2.

NO

System operating normally.

B1322-2 - Check Circuit 867 (DB)

-

Disconnect Lighting Control Module Connector C2.

-

Ensure that door is closed.

-

Using an ohmmeter, connect to ground, measure resistance at lighting control module connector Pin C3-8.

Is resistance less than 10K ohms?

YES

GO to B1322-3.

NO

REPLACE lighting control module.  RETEST system.

B1322-3 - Check Driver Door Ajar Switch

-

Disconnect LH front driver door ajar warning switch.

-

Using an ohmmeter connected to ground, measure resistance at lighting control module Pin C2-11, Circuit 867 (DB).

Is resistance 5 ohms or less?

YES

SERVICE Circuit 867 (DB) for short to ground.  RETEST system.

NO

SERVICE door ajar switch for stuck switch.  RETEST system.

B1566 - Door Ajar, Short To Ground

DTC B1566: Door Ajar - Short To Ground

NOTE: Ford DOES NOT provide a procedure to perform the following pinpoint test without the Rotunda New Generation Star (NGS) tester
007-00500 or equivalent.

B1566-1 - Rerun Test

-

Make sure that all doors are closed to second latch.

-

Repeat on-demand self-test.

Is DTC B1566 still present?

YES

GO to B1566-3.

NO

GO to B1566-2.

B1566-2 - Make Sure That Switch Is Not Sticking

-

Set NGS tester to read P_DR_LC PID.

-

Open and close doors several times.  Test passenger front and both rear doors.

Does PID show that doors are open and closed as expected?

YES

System operating normally.

NO

REPLACE door open warning lamp switch in door that was sticking.  RESTORE vehicle.  RETEST system.

B1566-3 - Check Door Lock Cylinder Switch PID

-

Set NGS tester to read P_DR_LC PID.

Does PID show "CLOSED"?

YES

REPLACE lighting control module.  RESTORE vehicle.  RETEST system.

NO

GO to B1566-4.

B1566-4 - Check Passenger Side Front Door Open Warning Lamp Switch

-

Disconnect passenger front door open warning lamp switch.

-

Set NGS tester to read P_DR_LIC PID.

Initial Inspection and Diagnostic Overview|Page 9276 > < Initial Inspection and Diagnostic Overview|Page 9274