ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 8531 > < Initial Inspection and Diagnostic Overview|Page 8529
Page 3
background image

-

Is the voltage greater than 10 volts?

Yes

GO to P5.

No

REPAIR circuit CLS30 (VT/WH) for an open. TEST the system for normal operation.

-------------------------------------------------
P5 CHECK FOR VOLTAGE TO THE INOPERATIVE PARKING LAMP USING THE CONNECTOR GROUND

 

-

Measure the voltage between the inoperative lamp, harness side as follows:

Initial Inspection and Diagnostic Overview|Page 8531 > < Initial Inspection and Diagnostic Overview|Page 8529