General Procedures Special Tool(s) | Actuator Cable 310-098 (23-068) | WARNING:Fuel supply lines will remain pressurized after shutdown. When servicing fuel related components, do not smoke or carry lighted tobacco or any open flame of any type. Flammable gases may be present and ignite. Failure to follow these instructions may result in personal injury. WARNING:This procedure involves fuel handling. Be prepared for fuel spillage at all times and always observe fuel handling precautions. Failure to follow these instructions may result in personal injury. WARNING:Never attempt to tighten or adjust fittings while the system is pressurized. Failure to follow this instruction may result in personal injury. WARNING:All gas lines must be installed prior to reconnecting the battery. Failure to follow this instruction may result in personal injury. WARNING:The fuel lines must be evacuated before attempting any repairs. Failure to follow these instructions may result in personal injury. | -
Disconnect the fuel tank electrical connector. | | -
Install the special tool wiring harness and connect to a 12V supply. | | -
Check for leaks over all of the unions with an electronic leak detector. If a leak is detected identify the exact union with a liquid leak detector. | | -
Repair the detected leak. Test the system for normal operation. | |