ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

303-03B Engine Cooling - 1.6L Duratec-16V Ti-VCT (Sigma) > < Cooling Fan Motor and Shroud
Engine Cooling - 1.4L Duratec-16V (Sigma)/1.6L Duratec-16V (Sigma) - Coolant Outlet Connector Focus 2004.75 (07/2004-)
Removal and Installation

Special Tool(s)

Remover/Installer, Coolant Hose Clamp

303-397

  1. Drain the cooling system.
    For additional information, refer to: Cooling System Draining, Filling and Bleeding.

2. Remove the components in the order indicated in the following illustration(s) and table(s).

 
Item
Part Number
Description
1
-
Spark plug wires
2
-
Ignition coil pack electrical connector
3
-
Ignition coil pack
5
-
Coolant expansion tank to coolant outlet connector coolant hose
See Removal Detail
6
-
Coolant outlet connector to heater core coolant hose
See Removal Detail
7
-
Radiator lower to coolant outlet connector coolant hose
See Removal Detail
8
-
Engine coolant temperature (ECT) sensor electrical connector
9
-
Coolant outlet connector
10
-
Coolant outlet connector gasket
11
-
Engine coolant temperature (ECT) sensor

3. To install, reverse the removal procedure.

Removal Details

Item 4 : Coolant expansion tank to coolant outlet connector coolant hose retaining clip

  1. Detach the coolant expansion tank to coolant outlet connector coolant hose retaining clip from the coolant hose.

Item 5 : Coolant expansion tank to coolant outlet connector coolant hose

  1. Using a suitable tool, disconnect the coolant expansion tank to coolant outlet connector coolant hose.

Item 6 : Coolant outlet connector to heater core coolant hose

  1. Using the special tool, disconnect the coolant outlet connector to heater core coolant hose.

Item 7 : Radiator lower to coolant outlet connector coolant hose

  1. Using the special tool, disconnect the coolant outlet connector to radiator coolant hose.