Removal and Installation Special Tool(s) | Disconnect Tool, Refrigerant Line 5/8" (black) 412-038 (34-003) | Removal CAUTION:Renew the suction accumulator only if moisture was able to enter the open system over an extended period (two to three hours). | -
Remove the retaining clips of the quick-release couplings on the refrigerant lines. | | -
CAUTION:Close off the refrigerant lines and the suction accumulator to prevent dirt ingress. Using the special tool, detach the refrigerant lines from the suction accumulator. | | -
Unscrew and remove the upper suction accumulator bolt. | | -
Detach the right wheelhouse trim panel and secure it to one side. | | -
Remove the suction accumulator. | Installation | -
NOTE:Install new refrigerant line O-rings. NOTE:Coat the refrigerant line O-rings with clean refrigerant oil before installation. Install the components in the reverse order. | | |